Release Notes

Table 42. User Interface Issues Fixed in Storage Center 7.3.1
Issue Description
SCOS-41051 When the Storage Manager Client is connected to a Storage Center through a Data Collector, the
Storage Manager Client does not allow you to change the name of an enclosure and asset tag.
SCOS-25031 After a controller failover, the peer controller might be reported as down by both SNMP and a
Storage Manager Client that is directly connected to the peer controller.
SCOS-14951 After deleting volumes and snapshots, Storage Center does not immediately report the deleted
volume space as free space for a disk folder.
Fixed Issues Related to User Management
The following issues related to user management are fixed in Storage Center 7.3:
Table 43. Fixed User Management Issues in Storage Center 7.3.1
Issue Description
SCOS-42985 A Storage Center user with privileges based on a Directory Group might be unable to set some user
preferences.
Fixed Issues Related to Virtual Volumes
The following issues related to virtual volumes are fixed in Storage Center 7.3:
Table 44. Fixed Virtual Volumes Issues in Storage Center 7.3.5
Issue Description
SCOS-52965 On a dual-controller storage system that is connected to an ESXi host with VVols, a controller might
reset because of an Inquiry VPD Response SCSI command sent to a Protocol Endpoint.
SCOS-52730 On a dual-controller storage system that is connected to an ESXi host with VVols, a controller might
reset because of a Report Target Port Groups SCSI command sent to a Protocol Endpoint.
Table 45. Fixed Virtual Volumes Issues in Storage Center 7.3.1
Issue Description
SCOS-47784 A dual-controller storage system might reset following the VMotion of a VM from a VVol container to
a regular Storage Center datastore.
Fixed Issues Related to Vendors
The following issues related to vendors are fixed in Storage Center 7.3:
Table 46. Fixed Vendors Issues in Storage Center 7.3
Issue Description
SQAI-7 Emulex 8 Gb Fibre Channel host bus adapters (for example, LPe1200x, LPe1205, and OEM
equivalents) are unable to boot from SAN when using Emulex boot code 7.x.
Storage Center 7.3 Release Notes 21