SC5020 and SC5020F Storage Systems Getting Started Guide Regulatory Model: E03T Regulatory Type: E03T001
Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. © 2017 – 2018 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries.
Setting Up the Storage System Consider the following best practices when setting up an SC5020 series storage system. • Dell recommends that you use a dedicated SAN network for data transmission when using a Fibre Channel or iSCSI storage system. • Always configure redundant data paths to provide alternate paths to and from the host server should one of the data paths become disabled.
CAUTION: Class I laser radiation when open, avoid exposure to beam. WARNING: Laser radiation, avoid direct exposure to beam. The unit is certified in the U.S. to conform to the requirements of DHHS 21 CFR, chapter 1 Subchapter J for Class I (1) laser products, and elsewhere is certified as a Class I laser product conforming to the requirements of IEC 60825-1:2007. Class I laser products are not considered to be hazardous.
Provides information about an SC5020 series storage system, such as hardware features, replacing hardware components, and technical specifications. • Dell Storage Manager Administrator’s Guide Provides instructions for using the Dell Storage Manager software. • Unisphere and Unisphere Central for SC Series Administrator’s Guide Provides instructions and information for managing storage systems using Unisphere and Unisphere Central for SC Series.
Figure 1. SC5020 Series Storage System Components 1 Documentation 2 Storage system 3 Rack rails 4 USB cables (2) 5 Power cables (2) 6 Front bezel Install the Storage System in a Rack Install the storage system and other Storage Center system components in a rack. About this task Mount the storage system and expansion enclosures in a manner that allows for expansion in the rack and prevents the rack from becoming top‐heavy. The SC5020 series storage system ships with a ReadyRails II kit.
Steps 1 Position the left and right rail end pieces labeled FRONT facing inward. 2 Align each end piece with the top and bottom holes of the appropriate U space. Figure 2. Attach the Rails to the Rack 3 Engage the back end of the rail until it fully seats and the latch locks into place. 4 Engage the front end of the rail until it fully seats and the latch locks into place. 5 Align the system with the rails and slide the storage system into the rack.
Figure 3. Slide the Storage System Onto the Rails 6 Lift the latches on each side of the front panel and tighten the screws to the rack.
Figure 4. Tighten the Screws If the Storage Center system includes expansion enclosures, mount the expansion enclosures in the rack. See the instructions included with the expansion enclosure for detailed steps. Install the Front Bezel Install the bezel on the front of the storage system. Steps 1 Hook the right end of the bezel onto the storage system.
Figure 5. Front Bezel 2 Insert the left end of the bezel into the securing slot until the release latch snaps into place. 3 Secure the bezel with the keylock. Next step Install the expansion enclosures in the rack. See the instructions included with the expansion enclosure or in the expansion enclosure Service Guide for detailed steps. Connect the Power Cables Connect power cables to the storage system. 1 Make sure that the power switches are in the OFF position before connecting the power cables.
Figure 6. Connect the Power Cables 3 Use the straps to secure the power cables to the storage system chassis. Figure 7. Secure the Power Cables 4 Plug the other end of the power cables into a grounded electrical outlet or a separate power source such as an uninterrupted power supply (UPS) or a power distribution unit (PDU).
NOM Information (Mexico Only) The following information is provided on the device described in this document in compliance with the requirements of the official Mexican standards (NOM): Importer Dell Inc. de México, S.A. de C.V Paseo de la Reforma 2620-11 ° Piso Col. Lomas Atlas 11950 México, D.F. Model number E03T Supply voltage 100–240 VAC (1378 W) 200–240 VAC (1485 W) Frequency 50/60 Hz Current consumption 16A-8.25A (1378 W) 8.
Storage Controllers controllers. If a power failure occurs, the battery backup unit provides power to the storage controller so that the write cache can be saved to an SSD within the storage controller. Storage Connectivity Configurations SC5020: Supports a total of 222 drives and up to 192 drives on a single SAS chain. The SAS chain supports up to sixteen SC400 expansion enclosures, eight SC420 expansion enclosures, or three SC460 expansion enclosures.
LED Indicators Front panel • • • One dual-color LED indicator for system status One single-color LED indicator for power status Identification button with a single-color LED Hard drive carrier • • One single-color activity LED One dual-color LED status indicator per drive Storage controller • Two single-color LEDs per Ethernet port indicating activity and link speed One dual-color LED per SAS connector indicating port activity and status One single-color LED indicating status One single-color LED in
Power Supply Units (PSU) Inlet Type C14 C20 C20 Available Hard Drive Power (Per Slot) Supported hard drive power consumption (continuous) Up to 1.2 A at +5 V Up to 0.5 A at +12 V Physical Height 13.34 cm (5.25 in.) Width 44.50 cm (17.5 in.) Depth 78.27 cm (31 in.) Approximate weight (maximum configuration) 43 kg (95 lb) Approximate weight without drives 32.
Environmental Maximum vibration Operating 0.26 Grms at 5–350 Hz for 15 min Storage 1.88 Grms at 10–500 Hz for 15 min Maximum shock Operating 31 G +/- 5% with pulse duration of 2.6 ms +/- 10% (equivalent to 20 in./sec [51 cm/sec]) Storage 71 G +/- 5% with pulse duration of 2 ms +/- 10% (equivalent to 35 in.