Setup Guide

Power Supply Units (PSU)
Inlet Type C14 C20 C20
Available Hard Drive Power (Per Slot)
Supported hard drive power
consumption (continuous)
Up to 1.2 A at +5 V
Up to 0.5 A at +12 V
Physical
Height 13.34 cm (5.25 in.)
Width 44.50 cm (17.5 in.)
Depth 78.27 cm (31 in.)
Approximate weight (maximum
conguration)
43 kg (95 lb)
Approximate weight without
drives
32.5 kg (72 lb)
Environmental
For additional information about environmental measurements for specic storage system
congurations, see dell.com/environmental_datasheets.
Temperature
Operating 10°C (50°F) to 35°C (95°F) with a maximum
temperature gradation of 20°C/hour (36°F/hour)
Operating above 35°C could result in data loss
Storage –40° to 65°C (40° to 149°F) at a maximum altitude
of 12,000 m (39,370 ft)
Relative humidity
Operating 10% to 80% (noncondensing) with 29°C (84.2°F)
maximum dew point
Storage 5% to 95% (noncondensing) with 33°C (91°F)
maximum dew point
Setting Up the Storage System 15