Setup Guide

Setting Up the Storage System
Consider the following best practices when setting up an SC5020 series storage system.
Dell recommends that you use a dedicated SAN network for data transmission when
using a Fibre Channel or iSCSI storage system.
Always congure redundant data paths to provide alternate paths to and from the host
server should one of the data paths become disabled.
Before connecting any cables between the storage system and host server or expansion
enclosure, physically label each port and connector.
Always follow proper power-up and power-down procedures when cycling power across
the network. Verify that critical network components are on separate power circuits.
NOTE: This product is intended for restricted access locations, such as a dedicated
equipment room or equipment closet.
WARNING: If installed in a closed or multi-unit rack assembly, the operating
ambient temperature of the rack environment may be greater than room ambient
temperature. Therefore, consideration should be given to installing the equipment in
an environment compatible with the maximum ambient temperature (Tma) specied
by the manufacturer.
Safety Warnings
Two person lift required
A fully congured SC5020 series storage system weighs
approximately 43 kg (95 lb). Use appropriate lifting
methods when installing the storage system.