Release Notes

Issue Description
Workaround: Remove the server from the cluster through the OS first. After the server is rebooted,
remove the server object using Dell Storage Manager.
SCOS-12067 When importing a volume, Storage Manager does not allow you to select 0 as the LUN number.
Workaround: None
Open Issues Related to Storage Management
The following open issues are related to Storage Management:
Table 39. Open Storage Management Issues
Issue Description
SCOS-14951 After deleting volumes and snapshots, Storage Center does not immediately report the deleted
volume space as free space for a disk folder.
Workaround: Contact Dell Technical Support.
Open Issues Related to Updating, SupportAssist, and
Licensing
The following open issues are related to updating , SupportAssist, and licensing:
Table 40. Open Updating, SupportAssist, and Licensing Issues
Issue Description
SCOS-18488 The Storage Center System Manager user interface is not disabled after updating a dual-controller
storage system from Storage Center 6.6.5 to Storage Center 7.1.1.
Workaround: Reboot the storage system.
Open Issues Related to Vendors
The following open issues are related to vendors:
Table 41. Open Vendor Issues
Issue Description
SCOS-18123 Fibre Channel volumes that are mapped to a Hyper-V virtual machine using NPIV are not discovered
by the virtual machine when the server has a QLogic HBA with out-of-date drivers.
Workaround: Update the HBA to the latest version of the QLogic driver listed in the Dell Storage
Compatibility Matrix.
SQAI-2 An ESXi 5.5 or 6.0 host with an Emulex FC/FCoE HBA running driver version 11.0.x.x might crash
during a controller failover.
Workaround: Update the Emulex FC/FCoE HBA to driver version 11.1.145.18 or later, which is available
on the VMware website.
SQAI-3 Software FCoE timeouts might occur when using QLogic CNAs in NIC mode.
Workaround: See the Dell Storage Compatibility Matrix for the list of supported firmware and drivers.
SCOS-10166 Emulex FC and FCoE driver version 10.7.170.0 might cause an ESXi 5.5 or 6.0 host to fail during
controller failovers.
Workaround: Use the latest recommended driver version for the Emulex adapters. See the Dell
Storage Compatibility Matrix.
22 Dell Storage Center 7.1 Release Notes