Administrator Guide

Table Of Contents
Steps
1. If you are connected to a Data Collector, select a Storage Center from the drop-down list in the left navigation pane of
Unisphere Central.
2. From the SYSTEM menu, click Ports.
The Ports view is displayed.
3. Click the Front End Ports tab.
4. Expand iSCSI and click the fault domain link..
The Fault Domain view is displayed.
5. In the Summary tab, click
(More Actions) and select Create VLAN Copy.
The Create VLAN Copy dialog box opens.
6. In the Name field, type a name for the fault domain.
7. Configure an IP address and gateway for the iSCSI control port in the fault domain. Servers target this IP address using
iSCSI initiators, and the Storage Center redirects individual iSCSI connections to the appropriate virtual port.
a. In the Target IPv4 Address field, type an IP address to assign to the iSCSI control port.
b. In the Subnet Mask field, type the subnet mask for the well-known IP address.
c. In the Gateway IPv4 Address field, type the IP address for the iSCSI network default gateway.
8. Configure VLAN tagging.
a. In the VLAN ID field, type the VLAN ID for the fault domain. Allowed values are 14096.
b. To assign a priority level to the VLAN, type a value from 07 in the Class of Service Priority field. 0 is best effort, 1 is
the lowest priority, and 7 is the highest priority.
9. Click OK.
Modifying iSCSI Fault Domains
Modify an iSCSI fault domain to change its name, modify network settings for iSCSI ports in the domain, add or remove iSCSI
ports, or delete the fault domain.
NOTE: For user interface reference information, click Help.
Rename an iSCSI Fault Domain
The fault domain name allows administrators to identify the fault domain.
Steps
1. If you are connected to a Data Collector, select a Storage Center from the drop-down list in the left navigation pane of
Unisphere Central.
2. From the
SYSTEM menu, click Ports.
The Ports view is displayed.
3. Click the Front End Ports tab.
4. Expand iSCSI and click the fault domain link.
The Fault Domain view is displayed.
5. On the Summary tab, click
(Edit).
The Edit iSCSI Fault Domain dialog box opens.
6. In the Name field, type a name for the fault domain.
7. Click OK.
Modify iSCSI Fault Domain Control Port Network Settings
Configure an IP address and gateway for the iSCSI control port in the fault domain. Servers target this IP address using iSCSI
initiators, and the Storage Center redirects individual iSCSI connections to the appropriate virtual port.
Prerequisites
The Storage Center iSCSI ports must be configured for virtual port mode.
Storage Center Maintenance
171