Administrator Guide

Table Of Contents
2. Click the Hardware tab.
3. In the Hardware tab navigation pane, expand Controllers and select the controller.
The Controller view is displayed.
4. In the right pane, click Shut Down/Restart Controller.
The Shut Down/Restart Controller dialog box opens.
5. From the drop-down menu, select Restart.
6. Click OK.
Reset a Controller to Factory Default
Reset a controller to apply the factory default settings, erase all data stored on the controller, and erase all data on the drives.
Prerequisites
The Storage Center must be an SCv2000 or SCv3000 series storage system.
About this task
CAUTION: Resetting the controller to factory defaults erases all information on the controller and all data on
the drives.
Steps
1. If the Storage Manager Client is connected to a Data Collector, select a Storage Center from the Storage view.
2. In the right pane, click Actions System Reset to Factory Defaults.
The Reset Storage Center to Factory Defaults dialog box opens.
3. In the Factory Reset Token field, type the text above the Factory Reset Token field exactly as it appears in the dialog
box.
4. In the Storage Center Administrator Username field type the username of a Storage Center user with administrator-level
privileges.
5. In the Storage Center Administrator Password field type the password of a Storage Center user with administrator-level
privileges.
6. To restart the controller after the reset, select the Power on the Storage Center after resetting to factory defaults
checkbox.
7. Click OK.
The Storage Center resets to the factory default settings.
Managing Field Replaceable Units (FRU)
The FRU Manager maintains the status of FRUs and issues action tickets when a unit needs to be replaced. Storage Manager
displays FRU tickets that contain specific information on each FRU, and provides the ability to close tickets.
NOTE: The FRU Manager is not supported on SC8000 or CT-SC040 series storage systems.
Managing FRU Tickets
Storage Manager can display information on FRU tickets, and can also close FRU tickets.
NOTE: If FRUs and FRU Manager are not enabled, Storage Manager does not display options or tickets.
View a FRU Ticket
To view the status of a replacement Field Replacement Unit (FRU) view the FRU ticket from the Alerts tab.
Steps
1. If the Storage Manager Client is connected to a Data Collector, select a Storage Center from the Storage view.
Storage Center Maintenance
297