Administrator Guide

2. Log in to Storage Manager using the following temporary user:
User name: config
Password: dell
The Getting Started page of the Data Collector Initial Setup wizard is displayed.
3. Click Next.
4. Select the Configure as Remote Data Collector radio button.
5. Specify the following information about the Primary Data Collector:
a) Type the hostname or IP address of the Primary Data Collector in the Server field.
b) In the Web Server Port field, type the port number of the Primary Data Collector web service.
The default port is 3033.
c) Type the user name of the administrator user on the Primary Data Collector in the User Name field.
d) Type the password of the administrator user on the Primary Data Collector in the Password field.
e) Select a time zone for the Primary Data Collector from the Timezone drop-down menu.
6. Click Next.
The Ports page appears.
7. To change the port number of a service or enable/disable a service:
a) Select the service to modify and click Edit.
The Edit Port dialog box open.
b) To change the port number of the service, type a different port number in the Port field.
c) To enable or disable the service, select or clear the Enabled check box.
d) Click OK.
8. Click Next.
The Summary page appears.
9. Verify the information on the Summary page.
10. Click Finish.
A confirmation dialog box is displayed.
11. Click Yes.
After the Remote Data Collector setup is complete, the Data Collector restarts, and the login page for Unisphere Central is displayed.
Disconnecting and Reconnecting a Remote Data
Collector
Perform these tasks to disconnect or reconnect a remote Data Collector.
NOTE: For user interface reference information, click Help.
Temporarily Disconnect a Remote Data Collector
Stop the Data Collector service on the remote Data Collector to temporarily disconnect it from the primary Data Collector.
Steps
1. On the remote Data Collector server:
a) Open the Data Collector.
b) On the General Information tab, click Stop to stop the Data Collector service.
2. Use the Storage Manager Client to connect to the primary Data Collector and log on.
3. Click the Replications & Live Volumes view, then click the Remote Data Collector tab.
The Connection Status of the remote Data Collector shows Down the next time the primary Data Collector attempts to synchronize
with the remote Data Collector.
Remote Data Collector
531