Release Notes

Table 11. Issues resolved in Storage Center 7.5.1 (continued)
Issue Functional area Description
SCOS-60805 Storage Management Distributed Spare Optimizer might fail to run if it is enabled on a storage system
during a Storage Center update.
SCOS-60788 Storage Management During a system restripe cycle, Storage Center might encounter a loop that
selects a pagepool device to prune as excess, prunes the device, and then re-
creates the device after it is pruned.
SCOS-60784 Storage Management In rare cases, two progression cycles might run simultaneously after controller
failover.
SCOS-60780 Storage Management In rare cases, data progression might stall due to a missed data progression
completion.
SCOS-60719 Storage Management Secondary storage might fail to load after rebooting a controller because of
inconsistent metadata.
SCOS-60380 Storage Management Storage Center might be unable to manage disks that have added to and
removed from a different storage system.
SCOS-60342 Storage Management Improved the KCS driver scheduling priority to reduce controller resets.
SCOS-60146 Storage Management A controller might reset because of an issue in the KCS driver.
SCOS-60097 Storage Management An Add Space operation might fail because the Block Device Identify process
pauses before releasing the disk management lock when the Disk Management
Discipline conflicts with disk label.
SCOS-60087 Storage Management A controller might reset due to resource allocation on KCS driver.
SCOS-60022 Storage Management Important update to detect KCS driver issues when a controller resets.
SCOS-59682 Storage Management Secondary storage might log an erroneous Emergency Mode message when a
storage system reboots.
SCOS-59665 Storage Management A controller might reset if a reqorder showdeadlocked command is
performed on an index that has over 12000 queued requests.
SCOS-59018 Storage Management Pagepool pages might be returned twice during a controller failover.
SCOS-58266 Storage Management In rare cases, an incomplete metadata cleanup operation might cause a controller
to reset and impact volume accessibility.
SCOS-56019 Storage Management A partial outage might occur if Storage Center tries to allocate resources for
certain types of SCSI Target requests, but not enough memory is available to
allocate the resources.
SCOS-61444 User Interface During a controller failover, the option to rebalance ports might be displayed in
the Storage Manager Client before the Storage Center is ready to perform a port
rebalance.
SCOS-60535 User Interface A controller might reset because of the format and length of the Uniform
Resource Identifier (URI) string that is used when configuring Directory Services.
SCOS-62474 User Interface When the Summary tab for a Storage Type is selected in Storage Manager Client
for a storage system with a distributed sparing enabled, the message Storage
Size is not a correct format might be displayed if the lowest index
disk in the Storage Type has more free space than other disks.
SCOS-59673 User Interface The calculation of Historical Available Space on a storage system might be
incorrect because the calculation does not subtract the Spare Block Count from
the Total Block Count.
SCOS-56519 User Interface Storage Center does not allow the privilege level of a directory user that is
managed at the individual level to become managed at a group level.
SCOS-60795 User Management Storage Center cannot authenticate directory service users that are configured
to use an alternate DNS suffix.
SCOS-60511 User Management Attempting to unlock a Storage Center user might fail if the user was locked
because of authentication failures.