Administrator Guide

a. Select the Enable SMTP Email check box.
b. In the SMTP Mail Server field, enter the IP address or fully qualified domain name of the SMTP email server. Click Test
Server to verify connectivity to the SMTP server.
c. (Optional) In the Backup SMTP Server field, enter the IP address or fully qualified domain name of a backup SMTP email
server. Click Test Server to verify connectivity to the SMTP server.
d. If the SMTP server requires emails to contain a MAIL FROM address, specify an email address in the Sender Email
Address field.
e. (Optional) In the Common Subject Line field, enter a subject line to use for all emails sent by the Storage Center.
f. Configure how the Storage Center identifies itself to the SMTP server:
To use SMTP, type the Storage Center fully qualified domain name in the Hello Message (HELO) field.
To use ESMTP, select the Send Extended Hello (EHLO) check box, then type the Storage Center fully qualified
domain name in the Extended Hello Message (EHLO) field.
g. If the SMTP server requires clients to authenticate before sending email, select the Use Authorized Login (AUTH LOGIN)
check box, then type a user name and password in the Login ID and Password fields.
6. Click OK.
Configure SNMP Settings for a Storage Center (Storage Center 6.7 and Earlier)
Configure SNMP if you want to monitor the Storage Center with a network management system.
1. Expand the Dell Storage Manager menu, and then click Storage.
2. In the SC Series tab, select a Storage Center to open the Storage Center view.
3. In the Summary tab, click Settings. The Edit Storage Center Settings dialog box opens.
4. Click the SNMP Server tab.
5. Set the community strings that allow access to the Storage Center SNMP agent.
a. In the Read Only Community String field, type a password for allowing network management systems to read from the
Storage Center SNMP agent.
b. In the Read Write Community String field, type a password for allowing network management systems to read from or
write to the Storage Center SNMP agent.
6. If the Agent Running status is Not Running, click Start Agent.
7. If the Storage Center supports SNMP v1 or v2, specify settings for the network management system to which Storage Center
will send SNMP traps.
a. In the Trap Community String field, type a password used to allow the Storage Center SNMP agent to communicate with
the Network Management System.
b. In the Trap Destination field, type host name or IP address of the Network Management System that is collecting trap
information.
c. From the Trap Type drop-down menu, select the trap type to use.
d. Click Start Trap.
8. When you are finished, click OK.
Configure SNMP Settings for a Storage Center (Storage Center Version 7.0 and Later)
Configure SNMP if you want to monitor the Storage Center with a network management system.
1. Expand the Dell Storage Manager menu, and then click Storage.
2. In the SC Series tab, select a Storage Center to open the Storage Center view.
3. In the Summary tab, click Settings. The Edit Storage Center Settings dialog box opens.
4. Click the SNMP Server tab.
5. From the SNMP Version drop-down menu, select the version of SNMP to be configured.
The contents of the dialog box change depending on the version selected.
6. If you selected SNMP v1 or v2, set the community strings that allow access to the Storage Center SNMP agent.
a. In the Read Only Community String field, type a password for allowing network management systems to read from the
Storage Center SNMP agent.
b. In the Read Write Community String field, type a password for allowing network management systems to read from or
write to the Storage Center SNMP agent.
72
Storage Center Maintenance