Administrator Guide
Steps
1. Congure the fault domain and ports (embedded fault domain 1 or Flex Port Domain 1).
NOTE: The Flex Port feature allows both Storage Center system management trac and iSCSI trac to use the
same physical network ports. However, for environments where the Storage Center system management ports are
mixed with network trac from other devices, separate the iSCSI trac from management trac using VLANs.
a. Enter the target IPv4 address, subnet mask, and gateway for the fault domain.
b. Enter an IPv4 address for each port in the fault domain.
NOTE: Make sure that all the IP addresses for the fault domain are in the same subnet.
2. Congure the fault domain and ports (embedded fault domain 2 or Flex Port Domain 2).
a. Enter the target IPv4 address, subnet mask, and gateway for the fault domain.
b. Enter an IPv4 address for each port in the fault domain.
NOTE: Make sure that all the IP addresses for the fault domain are in the same subnet.
3. Click OK.
Discover and Congure Uninitialized SCv2000 Series Storage Centers
(Fibre Channel/SAS)
When setting up the system, use the Discover and Congure Uninitialized Storage Centers wizard to nd new SCv2000 series
Storage Centers. The wizard helps set up a Storage Center to make it ready for volume creation.
Open the wizard from the Dell Storage Manager Client welcome screen or from the Dell Storage Manager Client.
Open the Discover and Congure Uninitialized Storage Centers Wizard From the Dell Storage
Manager Client Welcome Screen
Open the wizard directly from the welcome screen to discover and congure a Storage Center.
Prerequisites
• Client must be running on a system with a 64-bit operating system.
• The Dell Storage Manager Client must be run using Windows Administrator privileges.
Steps
1. Open the Dell Storage Manager Client welcome screen.
2. Click Discover and Congure Uninitialized Storage Centers.
The Discover and Congure Uninitialized Storage Centers wizard opens.
Open the Discover and Congure Uninitialized Storage Centers Wizard from the Dell Storage
Manager Client
Open the wizard from the Dell Storage Manager Client to discover and congure a Storage Center.
Prerequisites
• The Dell Storage Manager Client must be running on a system with a 64-bit operating system.
• The Dell Storage Manager Client must be run using Windows Administrator privileges.
• The client must be connected to a Storage Manager Data Collector.
Steps
1. Click the Storage view.
2. In the Storage pane, click Storage Centers.
3. In the Summary tab, click Discover and Congure Uninitialized Storage Centers .
The Discover and Congure Uninitialized Storage Centers wizard appears.
Storage Center Deployment
81