Administrator Guide

Steps
1. Congure the fault domain and ports (embedded fault domain 1 or Flex Port Domain 1).
NOTE: The Flex Port feature allows both Storage Center system management trac and iSCSI trac to use the
same physical network ports. However, for environments where the Storage Center system management ports are
mixed with network trac from other devices, separate the iSCSI trac from management trac using VLANs.
a. Enter the target IPv4 address, subnet mask, and gateway for the fault domain.
b. Enter an IPv4 address for each port in the fault domain.
NOTE: Make sure that all the IP addresses for the fault domain are in the same subnet.
2. Congure the fault domain and ports (embedded fault domain 2 or Flex Port Domain 2).
a. Enter the target IPv4 address, subnet mask, and gateway for the fault domain.
b. Enter an IPv4 address for each port in the fault domain.
NOTE: Make sure that all the IP addresses for the fault domain are in the same subnet.
3. Click OK.
Discover and Congure Uninitialized SCv2000 Series Storage Centers
(Fibre Channel/SAS)
When setting up the system, use the Discover and Congure Uninitialized Storage Centers wizard to nd new SCv2000 series
Storage Centers. The wizard helps set up a Storage Center to make it ready for volume creation.
Open the wizard from the Dell Storage Manager Client welcome screen or from the Dell Storage Manager Client.
Open the Discover and Congure Uninitialized Storage Centers Wizard From the Dell Storage
Manager Client Welcome Screen
Open the wizard directly from the welcome screen to discover and congure a Storage Center.
Prerequisites
Client must be running on a system with a 64-bit operating system.
The Dell Storage Manager Client must be run using Windows Administrator privileges.
Steps
1. Open the Dell Storage Manager Client welcome screen.
2. Click Discover and Congure Uninitialized Storage Centers.
The Discover and Congure Uninitialized Storage Centers wizard opens.
Open the Discover and Congure Uninitialized Storage Centers Wizard from the Dell Storage
Manager Client
Open the wizard from the Dell Storage Manager Client to discover and congure a Storage Center.
Prerequisites
The Dell Storage Manager Client must be running on a system with a 64-bit operating system.
The Dell Storage Manager Client must be run using Windows Administrator privileges.
The client must be connected to a Storage Manager Data Collector.
Steps
1. Click the Storage view.
2. In the Storage pane, click Storage Centers.
3. In the Summary tab, click Discover and Congure Uninitialized Storage Centers .
The Discover and Congure Uninitialized Storage Centers wizard appears.
Storage Center Deployment
81