The threshold alert is automatically set for the selected alert definition.
9. (Optional) To remove the Threshold Alert Definition, hold Ctrl and click the alert definition in the .Selected Alert
Definitions table, then hold Ctrl and click the threshold alert in the .Available Alert Definitions table.
The alert threshold is removed from the alert definition.
10. Click OK.
Configure Front-End I/O Ports (Fibre Channel and SAS)
On SCv2000 series and SCv3000 series storage systems, unconfigured Fibre Channel and SAS ports must be configured before
they can be used as front-end ports.
Steps
1. If the Storage Manager Client is connected to a Data Collector, select a Storage Center from the Storage view.
2. Click the Storage tab.
3. In the Storage tab navigation pane, select Fault Domains, then click the Unconfigured Ports subtab.
4. In the right pane, select an unconfigured Fibre Channel or SAS I/O port.
5. Click Configure Port.
Configure Front-End I/O Ports (iSCSI)
On SCv2000 series and SCv3000 series storage systems, unconfigured iSCSI ports must be configured before they can be used
as front-end ports..
Steps
1. If the Storage Manager Client is connected to a Data Collector, select a Storage Center from the Storage view.
2. Click the Storage tab.
3. In the Storage tab navigation pane, select Fault Domains, then click the Unconfigured Ports subtab.
4. In the right pane, select an unconfigured iSCSI I/O port.
5. Click Configure Port.
6. Type an IP address for the port.
7. Click OK.
Unconfigure Front-End I/O Ports
On SCv2000 series and SCv3000 series storage systems, unconfigure I/O ports that are not connected to the storage network
and are not intended for use.
Steps
1. If the Storage Manager Client is connected to a Data Collector, select a Storage Center from the Storage view.
2. Click the Storage tab.
3. In the Storage tab navigation pane, select Fault Domains, then click the Front End Ports subtab.
4. In the right pane, select a down I/O port and click Unconfigure Port.
The Unconfigure Port confirmation dialog box opens.
5. Click OK.