Owners Manual

Replacing Power Supply/Cooling Fan Modules
The SCv2000/SCv2020 storage system supports two hot-swappable power supply/cooling fan modules.
The cooling fans that cool the storage system and the power supplies are integrated into the power
supply/cooling fan module and cannot be replaced separately. If one power supply/cooling fan module
fails, the second module continues to provide power to the
storage system.
NOTE: When a power supply/cooling fan module fails, the cooling fan speed in the remaining
module increases significantly to provide adequate cooling. The cooling fan speed decreases
gradually when a new power supply/cooling fan module is installed.
Identifying the Failed Power Supply
To determine which power supply failed, use the Dell Storage Client.
1. Click the Hardware tab.
2. In the Hardware tab navigation pane, select and expand the failed storage system.
3. In the Hardware Alerts area, find the hardware alert that identifies the enclosure with the failed
power supply.
Figure 10. Hardware Alert Identifying the Enclosure with the Failed Power Supply
4. In the Hardware tab navigation pane, expand the enclosure identified in the previous step.
5. Select Power Supplies. The status of each power supply is displayed in the Power Supplies tab.
6. Select the failed power supply. The location of the failed power supply is displayed in the Power
Supply View tab.
Replacing SCv2000/SCv2020 Storage System Components
21