10. Push the release lever toward the chassis until it clicks into place. The storage controller is powered
on.
NOTE: When a storage controller is powered on, a oneminute delay occurs while the storage
controller prepares to boot. During this time, the only indication that the storage controller is
powered on are the LEDs on the storage controller. After the oneminute delay, the fans and
LEDs turn on to indicate that the storage controller is starting up.
11. In the Dell Storage Client, make sure that the replacement storage controller is recognized and
shown as up and running.
NOTE: If the Storage Center software on the replacement storage controller is older than the
software on the existing storage controller, the storage system updates the replacement
storage controller with the software version on the existing storage controller. The Storage
Center software update on the replacement storage controller could take 15 to 45 minutes to
complete.
12. Clear the swap status for the temperature sensor and I/O module.
a. Click the Hardware tab.
b. In the Hardware tab navigation pane, expand the enclosure.
c. Select Temperature Sensors.
d. In the right pane, right-click the sensor, then click Request Swap Clear.
e. Select I/O Modules.
f. In the right pane, right-click the module, then click Request Swap Clear.
g. Click the Alerts tab.
h. Right-click the alerts for the temperature sensor and I/O modules, then click Acknowledge.
NOTE: The alerts may not appear immediately. If the alerts do not appear, wait 10 seconds
and then click Refresh.
Next steps
Use SupportAssist to send diagnostic data to Dell Technical Support Services.
Replace Both Storage Controllers in Succession
Use this procedure to replace both storage controllers, one at a time.
Prerequisites
1. Use SupportAssist to send diagnostic data to Dell Technical Support Services.
2. Shut down the top storage controller.
About this task
This procedure is useful if you are swapping out degraded, but still operational, storage controllers.
Steps
1. Make sure all of the cables are labeled.
2. Disconnect all of the cables from the top storage controller.
3. Remove the battery from the top storage controller.
4. Push down on the release tab of the top storage controller and pull the release lever away from the
chassis.
NOTE: Wait until all of the storage controller indicators are off before removing the storage
controller.
5. Grasp the release lever and pull the storage controller away from the chassis.
Replacing SCv2000/SCv2020 Storage System Components
33