Administrator Guide

3. In the Storage tab navigation pane, select the volume in the Recycle Bin that you want to restore.
4. In the right pane, click Restore Volume. The volume is moved from the Recycle Bin to its previous location.
Empty the Recycle Bin
Empty the Recycle Bin if you are sure you want to delete the recycled volume(s).
About this task
CAUTION: After the Recycle Bin is emptied, data on a recycled volume(s) cannot be recovered.
Steps
1. Select a Storage Center from the Storage view. (Data Collector connected Storage Manager Client only)
2. Click the Storage tab.
3. In the Storage tab navigation pane, select Recycle Bin.
4. In the right pane, click Empty Recycle Bin. The Empty Recycle Bin dialog box opens.
5. Click OK to conrm that you want to permanently delete all volumes in the Recycle Bin.
Delete a Volume Folder
A volume folder must be empty before it can be deleted. If the deleted volumes from the folder are in the Recycle Bin, the volume
folder is not considered empty and cannot be deleted.
1. Click the Storage view.
2. In the Storage pane, select a Storage Center.
3. Click the Storage tab.
4. In the Storage tab navigation pane, select the volume folder you want to move.
5. In the right pane, click Delete. The Delete dialog box opens.
6. Click OK to delete the folder.
Managing Data Reduction
Data Reduction uses compression and deduplication to decrease the amount of disk space used by volume data. Compression
reduces the amount of space used by a volume by encoding data. Deduplication nds duplicate pages and removes them, conserving
the disk space that would be used by additional copies. When deduplication is used, compression is also applied to a volume.
NOTE: Data Reduction is available in Storage Center version 7.0 or later.
Data Eligible for Data Reduction
To reduce the impact of Data Reduction on read and write operations, a limited amount of data is eligible for compression and
deduplication. Data Reduction Input limits the type of data that is eligible for Data Reduction. The following options are available for
Data Reduction Input.
Inaccessible Snapshot Pages – Allows Data Reduction to process data frozen by a snapshot and made inaccessible by new data
written over the original data in the snapshot.
All Snapshot Pages – Allows Data Reduction to process data frozen by a snapshot.
Change the Data Reduction Input
Change the Data Reduction Input for a volume to change the type of data that compression and deduplication reduces.
Prerequisite
Data Reduction must be applied to the volume.
Steps
1. Select a Storage Center from the Storage view. (Data Collector connected Storage Manager Client only)
2. Click the Storage tab.
3. In the Storage tab navigation pane, select a volume.
4. In the right pane, click Edit Settings. The Edit Volume dialog box opens.
Storage Center Administration
133