Administrator Guide

Apply SMTP Settings to Multiple Storage Centers
SMTP settings that are assigned to a single Storage Center can be applied to other Storage Centers.
Prerequisite
The Storage Center must be added to Storage Manager using a Storage Center user with the Administrator privilege.
Steps
1. Click the Storage view.
2. In the Storage pane, select the Storage Center that has the settings you want to apply to other Storage Centers.
3. In the Summary tab, click Edit Settings. The Edit Settings dialog box appears.
4. Click the SMTP Server tab.
5. Select the Apply these settings to other Storage Centers check box.
6. Click Apply. The Select Storage Center dialog box appears.
7. Select the check box for each Storage Center to which you want to apply the settings.
8. When you are nished, click OK.
If a password is not congured or was modied, the dialog box closes.
If a password was congured previously and not modied, the SMTP Server Password dialog box appears.
9. (Password only) In the Password eld, type the password for SMTP, then click OK.
Conguring Storage Center SNMP Settings
SNMP allows the Storage Center to be monitored over the network.
NOTE: For user interface reference information, click Help.
Congure SNMP Settings for a Storage Center (Storage Center Version 7.0 and Later)
Congure SNMP if you want to monitor the Storage Center with a network management system.
Prerequisite
To use SNMP v3, the Storage Center must use Storage Center version 7.0 or later. The Storage Center must be added to Storage
Manager using a Storage Center user with the Administrator privilege.
Steps
1. Select a Storage Center from the Storage view. (Data Collector connected Storage Manager Client only)
2. In the Summary tab, click Edit Settings. The Edit Storage Center Settings dialog box opens.
3. Click the SNMP Server tab.
4. From the SNMP Version drop-down menu, select the version of SNMP to be congured.
The contents of the dialog box change depending on the version selected.
5. If you selected SNMP v1 or v2, set the community strings that allow access to the Storage Center SNMP agent.
a. In the Read Only Community String eld, type a password for allowing network management systems to read from the
Storage Center SNMP agent.
b. In the Read Write Community String eld, type a password for allowing network management systems to read from or
write to the
Storage Center SNMP agent.
6. If you selected SNMP v3, specify the users of SNMP v3 by selecting an existing user or creating a new one.
To create a new user:
a. Click Create SNMP v3 User.
The Create SNMP v3 User window opens.
b. In the Name eld, type a user name.
c. In the Password eld, type a password.
d. Select an authentication method from the Authentication Type drop-down menu.
e. Select an encryption type from the Encryption Type drop-down menu.
f. Click OK.