Administrator Guide
NOTE: For user interface reference information, click Help.
Rename a Front-End IO Port
Set a display name for a physical or virtual IO port to make it more identiable.
1. Select a Storage Center from the Storage view. (Data Collector connected Storage Manager Client only)
2. Click the Hardware tab.
3. In the Hardware tab navigation pane, expand Controllers→ controller name→ IO Ports→transport type, then select the IO port.
4. In the right pane, click Edit Settings. The Edit Settings dialog box opens.
5. In the Name eld, type a descriptive name for the IO port.
6. Click OK.
Reset a Front-End IO Port Name to the WWN
Reset a physical or virtual IO port name to the World Wide Name if you no longer need the descriptive name dened by an
administrator.
1. Select a Storage Center from the Storage view. (Data Collector connected Storage Manager Client only)
2. Click the Hardware tab.
3. In the Hardware tab navigation pane, expand Controllers→ controller name→ IO Ports→transport type, then select the IO port.
4. In the right pane, click Edit Settings. The Edit Settings dialog box appears.
5. Click Reset name to WWN.
6. Click OK.
Change the Preferred Physical IO Port for a Virtual IO Port
Under normal operating conditions, a FC or iSCSI virtual port is hosted by its preferred physical port.
Prerequisites
The fault domain must be congured for virtual port mode.
• If a Storage Center has IO ports with dierent performance characteristics, you may want to congure a virtual port to use a
particular physical port.
• If a physical port is removed from a Storage Center, the corresponding virtual port must be assigned to a dierent physical port.
• A single physical port can be the preferred port for multiple virtual ports.
Steps
1. Select a Storage Center from the Storage view. (Data Collector connected Storage Manager Client only)
2. Click the Hardware tab.
3. In the Hardware tab navigation pane, expand Controllers→ controller name→ IO Ports→transport type→physical IO port, then
select the virtual IO port.
4. In the right pane, click Edit Settings. The Edit Settings dialog box appears.
5. From the Preferred Parent drop-down menu, select the WWN of the physical IO port that should host the virtual port when
possible.
6. Click OK.
Set or Modify the IP Address and Gateway for a Single iSCSI Port
Servers target the iSCSI port IP address to initiate iSCSI connections to the Storage Center.
1. Select a Storage Center from the Storage view. (Data Collector connected Storage Manager Client only)
2. Click the Hardware tab.
3. In the Hardware tab navigation pane, expand Controllers→controller_name→ IO Ports→ iSCSI, then select the iSCSI IO port.
4. In the right pane, click Edit Settings. The Edit Settings dialog box opens.
5. In the IPv4 Address eld, type the new IPv4 address for the iSCSI I/O port.
6. Click OK.
266
Storage Center Maintenance