Administrator Guide

8. Assign a VLAN IP address to each selected port in the Ports table by editing the corresponding eld in the VLAN IP Address
column. Each port must have an IP address in the same network as the iSCSI control port, which is specied in the Well Known
IP Address eld.
9. Click OK.
Related link
Create a Virtual iSCSI Fault Domain
iSCSI VLAN Tagging Support
Multi-VLAN Tagging Requirements
Modifying iSCSI Fault Domains
Modify an iSCSI fault domain to change its name, modify network settings for iSCSI ports in the domain, add or remove iSCSI ports,
or delete the fault domain.
NOTE: For user interface reference information, click Help.
Rename an iSCSI Fault Domain
The fault domain name allows administrators to identify the fault domain.
1. Select a Storage Center from the Storage view. (Data Collector connected Storage Manager Client only)
2. Click the Storage tab.
3. In the Storage tab navigation pane, expand Fault DomainsiSCSI, then select the fault domain.
4. In the right pane, click Edit Settings. The Edit Settings dialog box opens.
5. In the Name eld, type a name for the fault domain.
6. Click OK.
Modify iSCSI Fault Domain Control Port Network Settings
Congure an IP address and gateway for the iSCSI control port in the fault domain. Servers target this IP address using iSCSI
initiators, and the Storage Center redirects individual iSCSI connections to the appropriate virtual port.
Prerequisite
The Storage Center iSCSI ports must be congured for virtual port mode.
Steps
1. Select a Storage Center from the Storage view. (Data Collector connected Storage Manager Client only)
2. Click the Storage tab.
3. In the Storage tab navigation pane, expand Fault DomainsiSCSI, then select the fault domain.
4. In the right pane, click Edit Settings. The Edit Settings dialog box opens.
5. In the Target IPv4 Address eld, type an IP address to assign to the iSCSI control port.
6. In the Subnet Mask eld, type the subnet mask for the well-known IP address.
7. In the Gateway IPv4 Address eld, type the IP address for the iSCSI network default gateway.
8. (Optional) If IPv6 is supported, in the Target IPv6 Address eld, type an IP address to assign to the iSCSI control port.
9. Click OK.
Add a VLAN ID to a Physical iSCSI Fault Domain
Add a VLAN ID to an existing iSCSI fault domain if the ports in the fault domain are connected to a tagged network.
Prerequisite
The Storage Center iSCSI ports must be congured for virtual port mode.
Steps
1. Select a Storage Center from the Storage view. (Data Collector connected Storage Manager Client only)
2. Click the Storage tab.
3. In the Storage tab navigation pane, expand Fault DomainsiSCSI, then select the fault domain.
274
Storage Center Maintenance