Clear the Minimum and Maximum Recorded Values for Temperature Sensor
Clear the minimum and maximum recorded values for a temperature sensor to reset them.
1. Select a Storage Center from the Storage view. (Data Collector connected Storage Manager Client only)
2. Click the Hardware tab.
3. In the Hardware tab navigation pane, select Temperature Sensors.
4. In the right pane, right-click the sensor, then click Request Min/Max Temps Clear.
Replace a Failed Cooling Fan Sensor
This step-by-step wizard guides you through replacing a failed cooling fan sensor in an enclosure in the Storage Center without a
controller outage.
Prerequisite
This wizard is only available for the SCv2000 series.
Steps
1. Select a Storage Center from the Storage view. (Data Collector connected Storage Manager Client only)
2. Expand Enclosures in the navigation pane. Select the enclosure with the failed cooling fan sensor, then select Temperature
Sensor.
3. Click Replace Failed Cooling Fan Sensor.
The Replace Failed Cooling Fan Sensor wizard appears.
4. Refer to the graphic in the wizard to locate the failed cooling fan sensor. Click Next.
5. Follow the instructions to remove the power supply from the enclosure. Click Next.
6. Follow the instructions to insert the replacement power supply. Click Next to verify the replacement.
If this verication fails, an error message appears. You can proceed to the next step once the error is corrected and validated.
7. Click Finish to exit the wizard.
Enable or Disable the Disk Indicator Light
The drive bay indicator light identies a drive bay so it can be easily located in an enclosure.
1. Select a Storage Center from the Storage view. (Data Collector connected Storage Manager Client only)
2. Click the Hardware tab.
3. In the Hardware tab navigation pane, expand the enclosure and select Disks.
4. In the right pane, select the disk, then click Indicator On/O.
Clear the Swap Status for a Disk
Clear the swap status for a disk to acknowledge that it has been replaced.
1. Select a Storage Center from the Storage view. (Data Collector connected Storage Manager Client only)
2. Click the Hardware tab.
3. In the Hardware tab navigation pane, select Disks.
4. In the right pane, select the disk, then click Request Swap Clear.
Managing Storage Center Controllers
Storage Manager can help you manage and maintain the controllers in your Storage Center.
Storage Manager can walk you through adding a controller, replacing a failed controller, replacing a failed cooling fan sensor, and
replacing a power supply.