Administrator Guide

Steps
1. Select a Storage Center from the Storage view. (Data Collector connected Storage Manager Client only)
2. Expand Enclosures in the navigation pane. Select the enclosure with the failed cooling fan sensor, then select Temperature
Sensor.
3. Click Replace Failed Cooling Fan Sensor.
The Replace Failed Cooling Fan Sensor wizard appears.
4. Refer to the graphic in the wizard to locate the failed cooling fan sensor. Click Next.
5. Follow the instructions to remove the power supply from the enclosure. Click Next.
6. Follow the instructions to insert the replacement power supply. Click Next to verify the replacement.
If this verication fails, an error message appears. You can proceed to the next step once the error is corrected and validated.
7. Click Finish to exit the wizard.
Congure Back-End Ports
Use the Generate Default Back End Port Conguration dialog box to congure back-end ports on CT-SC040 or SC8000 controllers.
After conguring the ports, they can be used to connect enclosures.
Prerequisites
Supports only CT-SC040, SC8000, or SC9000 controllers.
Back-end ports have not been previously congured during Storage Center conguration.
An enclosure must be connected to the ports.
Steps
1. Select a Storage Center from the Storage view. (Data Collector connected Storage Manager Client only)
2. Click the Storage tab.
3. In the Storage tab navigation pane, click Fault Domains.
4. Click Generate Default Back End Port Conguration.
The Generate Default Back End Port Conguration dialog box appears and displays the status of all SAS ports.
5. Click Finish to congure all SAS ports with a status of Up as back-end ports.
Managing IO Card Changes
The Congure IO Card Changes wizard simplies the task of moving, replacing, upgrading, or repurposing IO cards in Storage Center
controllers. The wizard is used to congure IO card hardware changes on a per-port basis after physical IO card changes have been
made. The wizard is typically used when upgrading IO cards or
controllers.
For each local port, you can specify:
Whether to link an IO card to an existing conguration
Whether the IO card is new hardware
Whether to delete the conguration for a removed IO card
The wizard guides you through the following actions:
Associating IO cards with existing port congurations
Indicating which IO cards are new hardware
Deleting congurations for IO cards that have been removed
Before using the wizard, you should be aware of the following:
Changes should be performed by a certied installer or with the assistance of Dell Technical Support.
At least one back-end port must remain in its original location.
A controller restart is required to implement changes.
Do not rebalance any ports until controller(s) have been replaced and all hardware conguration changes are complete.
Storage Center Maintenance