Administrator Guide
Steps
1. Select a Storage Center from the Storage view. (Data Collector connected Storage Manager Client only)
2. Expand Enclosures in the navigation pane. Select the enclosure with the failed cooling fan sensor, then select Temperature
Sensor.
3. Click Replace Failed Cooling Fan Sensor.
The Replace Failed Cooling Fan Sensor wizard appears.
4. Refer to the graphic in the wizard to locate the failed cooling fan sensor. Click Next.
5. Follow the instructions to remove the power supply from the enclosure. Click Next.
6. Follow the instructions to insert the replacement power supply. Click Next to verify the replacement.
If this verication fails, an error message appears. You can proceed to the next step once the error is corrected and validated.
7. Click Finish to exit the wizard.
Congure Back-End Ports
Use the Generate Default Back End Port Conguration dialog box to congure back-end ports on CT-SC040 or SC8000 controllers.
After conguring the ports, they can be used to connect enclosures.
Prerequisites
• Supports only CT-SC040, SC8000, or SC9000 controllers.
• Back-end ports have not been previously congured during Storage Center conguration.
• An enclosure must be connected to the ports.
Steps
1. Select a Storage Center from the Storage view. (Data Collector connected Storage Manager Client only)
2. Click the Storage tab.
3. In the Storage tab navigation pane, click Fault Domains.
4. Click Generate Default Back End Port Conguration.
The Generate Default Back End Port Conguration dialog box appears and displays the status of all SAS ports.
5. Click Finish to congure all SAS ports with a status of Up as back-end ports.
Managing IO Card Changes
The Congure IO Card Changes wizard simplies the task of moving, replacing, upgrading, or repurposing IO cards in Storage Center
controllers. The wizard is used to congure IO card hardware changes on a per-port basis after physical IO card changes have been
made. The wizard is typically used when upgrading IO cards or
controllers.
For each local port, you can specify:
• Whether to link an IO card to an existing conguration
• Whether the IO card is new hardware
• Whether to delete the conguration for a removed IO card
The wizard guides you through the following actions:
• Associating IO cards with existing port congurations
• Indicating which IO cards are new hardware
• Deleting congurations for IO cards that have been removed
Before using the wizard, you should be aware of the following:
• Changes should be performed by a certied installer or with the assistance of Dell Technical Support.
• At least one back-end port must remain in its original location.
• A controller restart is required to implement changes.
• Do not rebalance any ports until controller(s) have been replaced and all hardware conguration changes are complete.
Storage Center Maintenance