Administrator Guide

The hardware view indicates failed components with a red overlay.
5. To view more information about hardware components, mouse over a hardware component. A tool tip appears and displays
information including the name and status of the hardware component.
6. To adjust the zoom on the enclosure diagram, change the position of the zoom slider located to the right of the enclosure
diagram.
To zoom in, click and drag the zoom slider up.
To zoom out, click and drag the zoom slider down.
7. To move the enclosure diagram in the Enclosure View tab, click and drag the enclosure diagram.
View Alarm Status for an Enclosure
The Audible Alarms node on the Hardware tab displays alarm status for the enclosure.
1. Select a Storage Center from the Storage view. (Data Collector connected Storage Manager Client only)
2. Click the Hardware tab.
3. In the Hardware tab navigation pane, select Audible Alarms. The right pane displays summary information.
View Disk Status for an Enclosure
The Disks node in the Hardware tab displays the statuses of all disks in the enclosure.
1. Select a Storage Center from the Storage view. (Data Collector connected Storage Manager Client only)
2. Click the Hardware tab.
3. In the Hardware tab navigation pane, expand the Enclosure node then the node for a specic enclosure.
4. Click the Disks node. The right pane displays the status of all disks in the enclosure.
Locate a Disk in the Enclosure Diagram
The Hardware tab shows the location of a disk selected from the Disks tab in the right pane.
1. Select a Storage Center from the Storage view. (Data Collector connected Storage Manager Client only)
2. Click Hardware tab.
3. In the Hardware tab navigation pane, expand the Enclosures node, then the node for a specic enclosure.
4. Click the Disks node. The right pane displays the disks in the enclosure in the Disks tab.
5. Select a disk from the Disks tab. The Disk View tab highlights the disk in the enclosure diagram.
NOTE: Storage Manager groups disks in an SC280 enclosure into drawers. If the enclosure is an SC280, you must
expand a drawer to select a disk.
View Cooling Fan Status for an Enclosure
The Cooling Fan Sensors node on the Hardware tab displays cooling fan status for the enclosure.
1. Select a Storage Center from the Storage view. (Data Collector connected Storage Manager Client only)
2. Click the Hardware tab.
3. In the Hardware tab navigation pane, expand the Enclosures node, then the node for a specic enclosure.
4. Select Cooling Fan Sensors. The right pane displays summary information.
Locate a Cooling Fan Sensor in the Enclosure Diagram
The Hardware tab highlights the location of a cooling fan sensor in the enclosure diagram.
1. Select a Storage Center from the Storage view. (Data Collector connected Storage Manager Client only)
2. Click the Hardware tab.
3. In the Hardware tab navigation pane, expand the Enclosures node, then the node for a specic enclosure.
4. Click the Cooling Fan Sensors node. The right pane lists the cooling fan sensors in that enclosure.
5. Select a cooling fan sensor from the Cooling Fans tab. The Fan View tab highlights the selected fan in the enclosure diagram.
Viewing Storage Center Information
327