Administrator Guide

Viewing UPS Status
A UPS provides power redundancy to a Storage Center with the use of a backup battery.
If the power to a Storage Center is cut o, the UPS immediately switches over to the battery giving a Storage Center administrator
time to properly power down the Storage Center or x the power issue. When the UPS switches to the battery, it sends an on
battery message to the Storage Center. The Storage Center registers the battery message as an alert, turns o write cache, and
ushes the cache to disk. The Storage Center continues to operate in this way until it shuts down or the UPS sends an online
message allowing it to return to normal operations.
NOTE: For user interface reference information, click Help.
Related link
Add a UPS to a Storage Center
View Summary Information for All UPS Units that Serve the Storage Center
The UPS node on the Hardware tab displays summary information for the UPS units that provide backup power for the Storage
Center.
Prerequisite
A UPS unit must have been congured for the Storage Center.
Steps
1. Select a Storage Center from the Storage view. (Data Collector connected Storage Manager Client only)
2. Click the Hardware tab.
3. In the Hardware tab navigation pane, select UPS. The right pane displays summary information.
View Summary Information for a UPS Unit that Serves the Storage Center
The Hardware tab displays summary information for the UPS units that provide backup power for the Storage Center.
Prerequisite
A UPS must have been congured for the Storage Center.
Steps
1. Select a Storage Center from the Storage view. (Data Collector connected Storage Manager Client only)
2. Click the Hardware tab.
3. In the Hardware tab navigation pane, under the UPS node, select the name of a UPS unit. The right pane displays summary
information.