Administrator Guide

7. Enter any requested diagnostic parameters and click OK. The diagnostic parameters are described in the online help. After the
diagnostics have been run, Storage Manager will send diagnostic data using Dell SupportAssist.
Related link
Managing the FTP Server
Managing the FTP Server
Run Embedded System Diagnostics on a NAS Controller
The embedded system diagnostics (also known as Enhanced Pre-boot System Assessment (ePSA) diagnostics) provide a set of
options for particular device groups or devices.
Prerequisite
Connect a monitor to a NAS controller VGA port and connect a keyboard to one of the NAS controller USB ports.
About this task
The embedded system diagnostics allow you to:
Run tests automatically or in an interactive mode
Repeat tests
Display or save test results
Run thorough tests to introduce additional test options to provide extra information about the failed device(s)
View status messages that inform you whether tests are completed successfully
View error messages that inform you of problems encountered during testing
If a major component or device in the system does not operate properly, running the embedded system diagnostics might indicate
component failure. To run embedded system diagnostics, a NAS controller must be oine, which means it is not serving data.
The following table summarizes the embedded system diagnostics menu options.
Menu
Description
Conguration Displays the conguration and status information of all detected devices.
Results Displays the results of all tests that are executed.
System Health Provides the current overview of the system performance.
Event Log Displays a time-stamped log of the results of all tests run on the system. This is displayed if at least one
event description is recorded.
Steps
1. Press and release the recessed power button at the back of the NAS controller to shut down the NAS controller.
NOTE: Power o only the NAS controller on which you are running the embedded system diagnostics. Do not power
o the remaining NAS controllers. Powering o a NAS controller disconnects client connections while their clients
are being transferred to other NAS controllers. Clients will then automatically reconnect to the FluidFS cluster.
2. Press and release the recessed power button at the back of the NAS controller to turn on the NAS controller.
3. When you see the F10 = Launch Dell Embedded Diagnostics Module prompt, press F10. The ePSA Pre-boot System
Assessment window is displayed, listing all devices detected in the system. The diagnostics starts executing the tests on all the
detected devices.
4. After you are nished running the embedded system diagnostics, select Exit to exit the diagnostics and reboot the NAS
controller.
FluidFS Troubleshooting
645