Administrator Guide

Table Of Contents
5. In the Remote IPv4 Address field, type the IPv4 address of the external device.
6. From the iSCSI Network Type drop-down menu, select the speed of the iSCSI network.
7. Click Finish.
A confirmation dialog box appears.
8. Click OK.
PS Series Storage Array Import Requirements
A PS Series storage array must meet the following requirements to import data to a Storage Center storage system.
Component Requirement
PS Series Firmware Version 6.0.11 or higher
Connectivity iSCSI
Network Low-Latency, High-Bandwidth
Volume Settings
Limit access to the volume by Storage Center IP or iSCSI initiator name.
Enable Allow simultaneous connections from initiators with different IQNs in
the volume advanced settings.
Stop all IO from the server to the volume.
Storage Center Import Requirements
A Storage Center storage system must meet the following requirements to import data from a PS Series storage array.
Component
Requirement
Storage Center Version 7.1 or later
Connectivity iSCSI
Network Low-latency, high-bandwidth
MD Series Import Requirements
A PowerVault MD Series must meet the following requirements to import data to a Storage Center storage system.
Component
Requirement
Hardware Platforms MD3 series
Firmware Version 08.25.09
Supported Server Operating Systems for Online Import
Performing an online import of volumes from a PS Series storage array requires one of the following server operating systems:
Red Hat Enterprise Linux 6.7
Red Hat Enterprise Linux 7
SUSE Linux Enterprise 11 or 12
Oracle Linux 6.5
Oracle Linux 7.0
VMware ESXi 5.5 or later
Windows Server 2008 R2 or later
140
Storage Center Administration