Administrator Guide

e To create an SNMP v1 or v2 trap, in the Community String eld, type a password used to allow the Storage Center SNMP
agent to communicate with the network management system.
f To create an SNMP v3 trap, select a user from the SNMP v3 User drop-down menu.
g If you selected SNMP v1 or v2, to apply the changes to SNMP settings to other Storage Centers, check Apply these settings
to other Storage Centers.
h Click OK.
9 If the SNMP Running status is No, click Start SNMP.
10 Click OK.
Congure SNMP Settings for a Storage Center (Storage Center 6.7)
Congure SNMP if you want to monitor the Storage Center with a network management system.
Prerequisite
The Storage Center must be added to Storage Manager using a Storage Center user with the Administrator privilege. Storage Center 6.7
supports SNMP v1 and v2, but does not support. SNMP v3.
Steps
1 If the Storage Manager Client is connected to a Data Collector, select a Storage Center from the Storage view.
2 In the Summary tab, click Edit Settings.
The Edit Storage Center Settings dialog box opens.
3 Click the SNMP Server tab.
4 Set the community strings that allow access to the Storage Center SNMP agent.
a In the Read Only Community String eld, type a password for allowing network management systems to read from the Storage
Center SNMP agent.
b In the Read Write Community String eld, type a password for allowing network management systems to read from or write to
the Storage Center SNMP agent.
5 If the Agent Running status is Not Running, click Start Agent.
6 If the Storage Center supports SNMP v1 or v2, specify settings for the network management system to which Storage Center will
send SNMP traps.
a In the Trap Community String eld, type a password used to allow the Storage Center SNMP agent to communicate with the
Network Management System.
b In the Trap Destination eld, type host name or IP address of the Network Management System that is collecting trap
information.
c From the Trap Type drop-down menu, select the trap type to use.
d Click Start Trap.
7 Click OK.
Apply SNMP Settings to Multiple Storage Centers
SNMP settings that are assigned to a single Storage Center can be applied to other Storage Centers.
Prerequisite
The Storage Center must be added to Storage Manager using a Storage Center user with the Administrator privilege.
Steps
1 If the Storage Manager Client is connected to a Data Collector, select a Storage Center from the Storage view.
2 In the Summary tab, click Edit Settings.
The Edit Storage Center Settings dialog box opens.
3 Click the SNMP Server tab.
4 Select the Apply these SNMP v1/v2c settings to other Storage Centers checkbox.
5 Click Apply.
The Select Storage Center dialog box opens.
Storage Center Maintenance
239