Administrator Guide

Clear the Minimum and Maximum Recorded Values for
Temperature Sensor
Clear the minimum and maximum recorded values for a temperature sensor to reset them.
1 If the Storage Manager Client is connected to a Data Collector, select a Storage Center from the Storage view.
2 Click the Hardware tab.
3 In the Hardware tab navigation pane, expand Enclosures, then select and expand an enclosure.
The Enclosure view is displayed.
4 Under the selected enclosure, click Temperature Sensor.
The Temperature Sensors view is displayed.
5 In the right pane, select the temperature sensor, then click Request Min/Max Temps Clear.
Replace a Failed Cooling Fan Sensor
This step-by-step wizard guides you through replacing a failed cooling fan sensor in the Storage Center without a controller outage.
Prerequisite
This wizard is only available for the SCv2000 series and SCv3000 series Storage Centers.
Steps
1 If the Storage Manager Client is connected to a Data Collector, select a Storage Center from the Storage view.
2 Click the Hardware tab.
3 In the Hardware tab navigation pane, expand either Controllers or Enclosures, then select and expand either a controller or an
enclosure.
Either the Enclosure or Controller view is displayed.
4 Under the selected enclosure or controller, click Fan Sensors.
The Fan Sensors view is displayed.
5 In the right pane. select the failed sensor and click Replace Failed Cooling Fan Sensor.
The Replace Failed Cooling Fan Sensor wizard opens.
6 Refer to the graphic in the wizard to locate the failed cooling fan sensor. Click Next.
7 Follow the instructions to remove the power supply from the enclosure. Click Next.
8 Follow the instructions to insert the replacement power supply. Click Next to verify the replacement.
If this verication fails, an error message is displayed. You can proceed to the next step once the error is corrected and validated.
9 Click Finish to exit the wizard.
Enable or Disable the Disk Indicator Light
The drive bay indicator light identies a drive bay so it can be easily located in an enclosure.
1 If the Storage Manager Client is connected to a Data Collector, select a Storage Center from the Storage view.
2 Click the Hardware tab.
3 In the Hardware tab navigation pane, expand Enclosures, then select and expand an enclosure.
The Enclosure view is displayed.
4 Under the selected enclosure, click Disks.
The Disks view is displayed.
5 In the right pane, click the Disks subtab and select a disk.
Storage Center Maintenance