Administrator Guide

6 Enable or disable the disk indicator light for the selected disk.
If the indicator light is o, click Indicator On to enable the indicator light.
If the indicator light is on, click Indicator O to disable the indicator light.
Clear the Swap Status for a Disk
Clear the swap status for a disk to acknowledge that it has been replaced.
1 If the Storage Manager Client is connected to a Data Collector, select a Storage Center from the Storage view.
2 Click the Hardware tab.
3 In the Hardware tab navigation pane, expand Enclosures, then select and expand an enclosure.
The Enclosure view is displayed.
4 Under the selected enclosure, click Disks.
The Disks view is displayed.
5 In the right pane, click the Disks subtab, select a disk, then click Request Swap Clear.
Managing Storage Center Controllers
Storage Manager can help you manage and maintain the controllers in your Storage Center by walking you through the process for adding
a controller and replacing parts.
Add a Controller
This step-by-step wizard guides you through adding a new controller to the storage system.
Prerequisites
This wizard is only available for SC4020, SC8000, and SC9000 controllers.
The new controller must have a Hardware Serial Number (HSN) and Eth 1 IP address assigned to it before starting this procedure. To
see the new controller information, run the following command from the serial console:
controller show
Steps
1 If the Storage Manager Client is connected to a Data Collector, select a Storage Center from the Storage view.
2 Click the Hardware tab.
3 In the Hardware tab navigation pane, click Controllers.
The Controllers view is displayed.
4 Click Add Controller.
The Add New Controller wizard opens.
5 Conrm the details of your current install, and click Next.
6 Insert the controller into the existing enclosure. Click Next to validate the install.
7 Click Finish to exit the wizard.
Replace a Failed Controller
This step-by-step wizard guides you through replacing a failed controller in the Storage Center without an additional controller outage.
Prerequisite
This wizard is only available for the SCv2000 series controllers
304