Administrator Guide

Steps
1 If the Storage Manager Client is connected to a Data Collector, select a Storage Center from the Storage view.
2 Click the Hardware tab.
3 In the Hardware tab navigation pane, click Controllers.
The Controllers view is displayed.
4 In the right pane, select the controller you want to replace and click Replace Controller.
The Replace Controller wizard opens.
5 Refer to the graphic in the wizard to located the failed controller. Click Next.
6 Follow the instructions to remove the battery from the failed controller. Click Next.
7 Follow the instructions to remove the failed controller from the Storage Center. Click Next.
8 Insert the battery from the failed controller into the new controller. Click Next.
9 Follow the instructions to insert the new controller into the Storage Center. Click Next to validate the installation.
If the installation fails, an error message is displayed. You can proceed to the next step once the error is corrected and validated.
10 Click Finish to exit the wizard.
Enable or Disable a Controller Indicator Light
Enable a controller indicator light to assist in locating the controller in the rack.
Prerequisite
The controller indicator light is visible only on SC8000 or SC9000 storage controllers.
Steps
1 If the Storage Manager Client is connected to a Data Collector, select a Storage Center from the Storage view.
2 Click the Hardware tab.
3 In the Hardware tab navigation pane, expand Controllers, then select a controller.
The Controller view is displayed.
4 Enable or disable the disk indicator light for the selected disk.
If the indicator light is o, click Indicator On to enable the indicator light.
If the indicator light is on, click Indicator O to disable the indicator light.
Replace a Failed Cooling Fan Sensor
This step-by-step wizard guides you through replacing a failed cooling fan sensor in the Storage Center without a controller outage.
Prerequisite
This wizard is only available for the SCv2000 series and SCv3000 series Storage Centers.
Steps
1 If the Storage Manager Client is connected to a Data Collector, select a Storage Center from the Storage view.
2 Click the Hardware tab.
3 In the Hardware tab navigation pane, expand either Controllers or Enclosures, then select and expand either a controller or an
enclosure.
Either the Enclosure or Controller view is displayed.
4 Under the selected enclosure or controller, click Fan Sensors.
The Fan Sensors view is displayed.
5 In the right pane. select the failed sensor and click Replace Failed Cooling Fan Sensor.
The Replace Failed Cooling Fan Sensor wizard opens.
6 Refer to the graphic in the wizard to locate the failed cooling fan sensor. Click Next.
7 Follow the instructions to remove the power supply from the enclosure. Click Next.
8 Follow the instructions to insert the replacement power supply. Click Next to verify the replacement.
Storage Center Maintenance