Administrator Guide

4 Click I/O Modules. The right pane displays status information for the IO module selected from the I/O Modules tab.
Locate an IO Module in the Enclosure Diagram
The Hardware tab highlights the location of an IO module in the enclosure diagram.
1 If the Storage Manager Client is connected to a Data Collector, select a Storage Center from the Storage view.
2 Click the Hardware tab.
3 In the Hardware tab navigation pane, expand the Enclosures node then, the node for a specic enclosure.
4 Select the I/O Modules node. The right pane lists the IO modules in the enclosure.
5 Select an IO module from the I/O Modules tab. The IO Module View tab highlights the selected IO module in the enclosure diagram.
View Power Supply Status for an Enclosure
The Power Supplies node on the Hardware tab displays power supply status for the enclosure.
1 If the Storage Manager Client is connected to a Data Collector, select a Storage Center from the Storage view.
2 Click the Hardware tab.
3 In the Hardware tab navigation pane, expand the Enclosures node, then the node for a specic enclosure.
4 Click Power Supplies. The right pane displays status information for the power supply selected from the Power Supplies tab.
Locate a Power Supply in the Enclosure Diagram
The Hardware tab highlights the location of a power supply in the enclosure diagram.
1 If the Storage Manager Client is connected to a Data Collector, select a Storage Center from the Storage view.
2 Click the Hardware tab.
3 In the Hardware tab navigation pane, expand the Enclosures node, then the node for a specic enclosure.
4 Select the Power Supplies node. The right pane lists the power supplies in the enclosure.
5 Select a power supply from the Power Supplies tab. The Power Supply View tab highlights the selected power supply in the enclosure
diagram.
View Temperatures for an Enclosure
The Temperature Sensor node on the Hardware tab displays temperatures for the enclosure.
1 If the Storage Manager Client is connected to a Data Collector, select a Storage Center from the Storage view.
2 Click the Hardware tab.
3 In the Hardware tab navigation pane, expand the Enclosures node, then the node for a specic enclosure.
4 Click Temperature Sensor. The right pane displays temperature sensor information.
Monitoring SSD Endurance
The lifespan of a Solid State Drive (SSD) is determined by how much data is written to it. The endurance level for an SSD is displayed as a
percentage that indicates the amount of wear life remaining. Some SSDs track and report endurance status and some do not.
A fresh drive starts with an endurance level of 100%, and the endurance level decreases as data is written to the drive. A Storage Center
triggers an alert when it determines that an SSD will reach its endurance limit within 120 days.
NOTE
: For user interface reference information, click Help.
Viewing Storage Center Information 341