Deployment Guide

Item Control/Feature Icon Description
8 Storage controller fault
Off: No faults
Steady amber: Firmware has detected an error
Blinking amber:Storage controller is performing POST
9 Recessed reset button Not currently used
10 Identification LED
Off: Identification disabled
Blinking blue (for 15 sec.): Identification is enabled
Blinking blue (continuously): Storage controller shut down to the Advanced
Configuration and Power Interface (ACPI) S5 state
11 USB port One USB 3.0 connector
12 Diagnostic LEDs (8)
Green LEDs 0–3: Low byte hex POST code
Green LEDs 4–7: High byte hex POST code
13 Serial port (3.5 mm mini jack) Not for customer use
14 Two options:
Four iSCSI ports (Slot 1/
Port 1, Slot 1/Port 2, Slot
1/Port 3, and Slot 1/Port 4)
with two LEDs per port
Two iSCSI ports (Slot 1/
Port 1 and Slot 1/Port 2)
with two LEDs per port
Off: No power
Steady Amber: Link
Blinking Green: Activity
15 Mini-SAS port B (Slot 2/Port
2)
Back-end expansion port B
16 Mini-SAS port A (Slot 2/Port
1)
Back-end expansion port A
SCv2000/SCv2020 Storage System Storage Controller with Front-End SAS Ports
The following figure shows the features and indicators on a storage controller with front-end SAS ports.
Figure 12. SCv2000/SCv2020 Storage System Storage Controller with Four 12 Gb Front-End SAS Ports
Item
Control/Feature Icon Description
1 Battery status indicator
Blinking green (on 0.5 sec. / off 1.5 sec.): Battery heartbeat
Fast blinking green (on 0.5 sec. / off 0.5 sec.): Battery is charging
Steady green: Battery is ready
2 Battery fault indicator
Off: No faults
Blinking amber: Correctable fault detected
Steady amber: Uncorrectable fault detected; replace battery
About the SCv2000/SCv2020 Storage System
19