Deployment Guide

b. Connect a SAS cable from storage controller 2: port 1 to the first SAS HBA on host server 1.
2. Connect fault domain 2 (shown in blue) to host server 1.
a. Connect a SAS cable from storage controller 1: port 2 to the second SAS HBA on host server 1.
b. Connect a SAS cable from storage controller 2: port 2 to the second SAS HBA on host server 1.
3. Connect fault domain 3 (shown in gray) to host server 2.
a. Connect a SAS cable from storage controller 1: port 3 to the first SAS HBA on host server 2.
b. Connect a SAS cable from storage controller 2: port 3 to the first SAS HBA on host server 2.
4. Connect fault domain 4 (shown in red) to host server 2.
a. Connect a SAS cable from storage controller 1: port 4 to the second SAS HBA on host server 2
b. Connect a SAS cable from storage controller 2: port 4 to the second SAS HBA on host server 2
Example
Figure 49. Storage System with Dual 12 Gb SAS Storage Controllers Connected to Two Host Servers
1.
Server 1 2. Server 2
3. Storage system 4. Storage controller 1
5. Storage controller 2
Next steps
Install or enable MPIO on the host servers.
NOTE: After the Storage Center configuration is complete, run the host access wizard to configure host server access
and apply MPIO best practices. For the latest best practices, see the Dell Storage Center Best Practices document on
the
Dell TechCenter site (http://en.community.dell.com/techcenter/storage/).
Two Servers Connected to a Single 12 Gb 4-Port SAS Storage Controller
A storage system with four 12 Gb front-end SAS ports on a single storage controller can connect up to two host servers, if each
host server has two SAS HBAs.
About this task
This configuration includes four fault domains and the storage controller is connected to each host server using two SAS
connections.
NOTE: This configuration is vulnerable to storage controller unavailability, which results in a loss of connectivity between
the host servers and the storage system.
54