Deployment Guide

Back-End Connections for an SCv2000/SCv2020 Storage System
Without Expansion Enclosures
When you deploy an SCv2000/SCv2020 storage system without expansion enclosures, you must interconnect the storage
controllers using SAS cables. A single controller system should not connect a back-end SAS cable from port A to port B.
NOTE: The top storage controller is storage controller 1 and the bottom storage controller is storage controller 2.
Figure 61. SCv2000/SCv2020 Without Expansion Enclosures
1. SCv2000/SCv2020 storage system 2. Storage controller 1
3. Storage controller 2
The following table describes the back-end SAS connections for an SCv2000/SCv2020 storage system without expansion
enclosures.
Table 3. Storage System Without Expansion Enclosures
Path Connections
Chain 1: A Side (Orange) Storage controller 1: port A to storage controller 2: port B.
Chain 1: B Side (Blue) Storage controller 2: port A to the storage controller 1: port B.
Back-End Connections for an SCv2000/SCv2020 Storage System
With Expansion Enclosures
The SCv2000/SCv2020 storage system supports a total of 168 disks per Storage Center system.
The SCv2000 supports up to thirteen SC100 expansion enclosures, up to six SC120 expansion enclosures, or any combination of
SC100/SC120 expansion enclosures as long as the total disk count of the system does not exceed 168.
The SCv2020 supports up to twelve SC100 expansion enclosures, up to six SC120 expansion enclosures, or any combination of
SC100/SC120 expansion enclosures as long as the total disk count of the system does not exceed 168 disks.
NOTE: The SCv2000/SCv2020 storage system does not support the SC180.
The following sections show common cabling between the SCv2000/SCv2020 and SC100/SC120 expansion enclosures. Locate the
scenario that most closely matches the Storage Center that you are configuring and follow the instructions, modifying them as
necessary.