Deployment Guide

SUSE Linux Enterprise 12 or later
Windows Server 2008 R2 or later
Install and Use the Dell Storage Manager Client
You must start the Dell Storage Manager Client as an Administrator to run the Discover and Configure Uninitialized Storage Centers
wizard.
1. Go to www.dell.com/support, navigate to the SCv2000/SCv2020 product support page, and download the Windows or Linux
version of the Dell Storage Manager Client.
2. Install the Dell Storage Manager Client on the host server.
To discover and configure a Storage Center, the software must be installed on a host server that is on the same subnet as the
storage system.
3. To start the software on a Windows computer, right-click on the Dell Storage Manager Client shortcut and select Run as
administrator. To start the software on a Linux computer, execute the command ./Client from the var/lib/dell/bin
directory.
4. Click Discover and Configure Uninitialized Storage Centers. The Discover and Configure Uninitialized Storage Centers
wizard appears.
Discover and Select an Uninitialized Storage Center
The first page of the Discover and Configure Uninitialized Storage Centers wizard provides a list of prerequisite actions and
information required before setting up a
Storage Center.
Prerequisites
The host server, on which the Dell Storage Manager Client software is installed, must be on the same subnet or VLAN as the
Storage Center.
Temporarily disable any firewall on the host server that is running the Dell Storage Manager Client.
Layer 2 multicast must be allowed on the network.
Make sure that IGMP snooping is disabled on the switch ports connected to the Storage Center.
Steps
1. Make sure that you have the required information that is listed on the first page of the wizard. This information is needed to
configure the Storage Center.
2. Click Next. The Select a Storage Center to Initialize page appears and lists the uninitialized Storage Centers discovered by
the wizard.
NOTE: If the wizard does not discover the Storage Center that you want to initialize, perform one of the following
actions:
Make sure that the Storage Center hardware is physically attached to all necessary networks.
Make sure that the Storage Center is turned on for at least five minutes and does not display a fault LED.
Make sure that the diagnostic LEDs on the controllers are lit to indicate that the Storage Center is fully booted. See
Figure 68. Storage Controller Diagnostic LEDs.
Click Rediscover.
Click Troubleshoot Storage Center Hardware Issue to learn more about reasons why the Storage Center is not
discoverable.
Click Manually Discover Storage Center via MAC Address to enter the MAC address for the Storage Center.
If the previous actions do not work, manually deploy the Storage Center. See Deploy the Storage Center Using the
Direct Connect Method.
3. Select the Storage Center to initialize.
4. (Optional) Click Enable Storage Center Indicator to turn on the indicator light for the selected Storage Center. You can use
the indicator to verify that you have selected the correct Storage Center.
5. Click Next.
72
Discover and Configure the Storage Center