Administrator Guide

Table Of Contents
Enable or Disable the Disk Indicator Light
The drive bay indicator light identifies a drive bay so it can be easily located in an enclosure.
Steps
1. If the Storage Manager Client is connected to a Data Collector, select a Storage Center from the Storage view.
2. Click the Hardware tab.
3. In the Hardware tab navigation pane, expand Enclosures, then select and expand an enclosure.
The Enclosure view is displayed.
4. Under the selected enclosure, click Disks.
The Disks view is displayed.
5. In the right pane, click the Disks subtab and select a disk.
6. Enable or disable the disk indicator light for the selected disk.
If the indicator light is off, click Indicator On to enable the indicator light.
If the indicator light is on, click Indicator Off to disable the indicator light.
Clear the Swap Status for a Disk
Clear the swap status for a disk to acknowledge that it has been replaced.
Steps
1. If the Storage Manager Client is connected to a Data Collector, select a Storage Center from the Storage view.
2. Click the Hardware tab.
3. In the Hardware tab navigation pane, expand Enclosures, then select and expand an enclosure.
The Enclosure view is displayed.
4. Under the selected enclosure, click Disks.
The Disks view is displayed.
5. In the right pane, click the Disks subtab, select a disk, then click Request Swap Clear.
Managing Storage Center Controllers
Storage Manager can help you manage and maintain the controllers in your Storage Center by walking you through the process
for adding a controller and replacing parts.
Add a Controller
This step-by-step wizard guides you through adding a new controller to the storage system.
Prerequisites
This wizard is only available for SC4020, SC8000, and SC9000 controllers.
The new controller must have a Hardware Serial Number (HSN) and Eth 1 IP address assigned to it before starting this
procedure. To see the new controller information, run the following command from the serial console:
controller show
Steps
1. If the Storage Manager Client is connected to a Data Collector, select a Storage Center from the Storage view.
2. Click the Hardware tab.
3. In the Hardware tab navigation pane, click Controllers.
The Controllers view is displayed.
4. Click Add Controller.
290
Storage Center Maintenance