Document Number: 680-050-018 Rev. F 2019 - 06 Storage Manager 2018 R1 Release Notes Storage Manager allows an administrator to manage and monitor multiple Storage Centers, PS Series groups, and FluidFS clusters. Storage Manager 2018 R1 introduces new features and enhancements, and fixes issues present in the previous release. Current Version: 2018 R1.20 Release Date: 2018-11 Previous Version: 2018 R1.
Product Versions NOTE: Storage Manager 2018 R1.10 can be used to connect to a storage system running Storage Center 6.6 and update it to a later supported version of Storage Center PS Series group firmware 7.0–10.0 Dell FluidFS 6.0.300135 NOTE: You must update FluidFS firmware to 6.0.300135 before updating to Storage Manager 2018 R1. Microsoft System Center Virtual Machine Manager (SCVMM) 2012, 2012 SP1, 2012 R2, and 2016 VMware vCenter Site Recovery Manager (SRM) 5.8, 6.0, 6.1.1, 6.5, and 8.
Component Requirements NOTE: Linux versions of the Storage Manager Client support only 64-bit microprocessors. Software Linux VM Access Client Web browser Microsoft .NET Framework 4.0 (Windows only) • • VMware vSphere Web Client Hyper-V Manager Any of the following web browsers: • • • • Google Chrome Internet Explorer 11 Microsoft Edge Mozilla Firefox NOTE: Google Chrome is the recommended browser. Other web browsers might work but are not officially supported.
Component Requirements Web browser Any of the following web browsers: • • • • Google Chrome Internet Explorer 11 Microsoft Edge Mozilla Firefox NOTE: Google Chrome is the recommended browser. Other web browsers might work but are not officially supported.
Server Agent Requirements The following table lists the requirements for running the Storage Manager Server Agent on Windows servers. Component Requirements Operating system Any of the following 64-bit operating systems (with the latest service packs): • • • • Windows Server 2012 (full or core installation) Windows Server 2012 R2 (full or core installation) Windows Server 2016 Windows Server 2019 CPU 64-bit (x64) microprocessor Software Microsoft .NET Framework 4.
Conservation and Emergency Mode The Conservation Mode threshold has been changed to 0.5 percent of the usable space in a storage system. The minimum amount of usable space might range from 100 GB to 2 TB, depending on size of the storage system. When a storage system enters Conservation Mode, the volume queue depth is limited to reduce the rate at which servers consume space. Snapshots no longer expire automatically when a storage system is in Conservation or Emergency mode.
Distributed Sparing Distributed sparing allocates spare disk space across all drives rather than reserving an entire drive as a spare. Distributed sparing enables the storage system to use all disks in a balanced and optimized manner, which ensures the fastest recovery time following a drive failure. After a storage system is updated to Storage Center 7.3, it automatically manages all spare drives and prompts the user to enable the Spare Optimizer feature.
Replication for SCv2000 Series Storage Systems Replication is now supported between SCv2000 Series storage systems and the following storage systems: • SC9000 • SC8000 • SC7020F • SC7020 • SC5020F • SC5020 • SC4020 • SCv3000 Series SRA Improvements Changes made to SRA code and API resolve issues found in SRA operation, resulting in: • Improved SRA error handing and reporting. • Better stability in multi-threaded environment. • Resolution to generating duplicate volume IDs.
Fixed Issues The following sections summarize the issues fixed in Storage Manager 2018 R1. Fixed Issues Related to Cross-Platform Replication The following issues related to cross-platform replication are fixed in Storage Manager 2018 R1: Table 1. Issues Fixed in Storage Manager 2018 R1 Issue Description DSM-33154 Unable to replicate a Storage Center volume to a PS Group when the Storage Center volume has enabled the Duplication or Duplication and Compression settings.
Fixed Issues Related to the Data Collector The following issues related to the Data Collector are fixed in Storage Manager: Table 2. Issues Fixed in Storage Manager 2018 R1 Issue Description DSM-38789 The vSphere/vCenter integration in the Servers view of Storage Manager does not support ESXi hosts connected to a Storage Center via SAS. Documentation updated to clarify this limitation. Table 3.
Fixed Issues Related to FluidFS The following issues related to FluidFS are fixed in Storage Manager 2018 R1: Table 6. Issues Fixed in Storage Manager 2018 R1 Issue Description DSM-36182 When a FluidFS Admin user becomes temporarily blocked from logging into FluidFS due to an incorrect password, it causes all Admin users to be disconnected from FluidFS and requires them to reconnect by reentering their credentials.
Fixed Issues Related to Management of PS Series Groups The following issues related to management of PS Series Groups are fixed in Storage Manager 2018 R1: Table 10. Issues Fixed in Storage Manager 2018 R1 Issue Description DSM-30110 Adding and removing PS Series storage arrays can cause a memory leak in Storage Manager resulting in degraded Storage Manager performance. DSM-15839 After updating a PS Series group managed by Storage Manager from version 8.0 to 9.
Fixed Issues Related to Dell Storage Replication Adapter (SRA) The following issues related to Dell Storage Replication Adapter (SRA) are fixed in Storage Manager 2018 R1: Table 13. Issues Fixed in Storage Manager 2018 R1.10 Issue Description DSM-35711 Restore points for replicated volumes are not saved during the last step of the reprotect workflow. Table 14. Issues Fixed in Storage Manager 2018 R1.
Table 17. Issues Fixed in Storage Manager 2018 R1.10 Issue Description DSM-38641 Applying a snapshot profile to a volume that is the source of a replication might fail in Storage Manager. DSM-38565 The Storage Manager Server Agent might format Windows 2016 volumes using MBR instead of GPT. DSM-37720 The Edit Data Collector Settings dialog box can be accessed from the Reports view by Storage Manager users with Reporter privileges.
Fixed Issues Related to the Storage Manager User Interface The following issues related to the Storage Manager user interface are fixed in Storage Manager 2018 R1: Table 19. Open Issues in Storage Manager 2018 R1.20 Issue Description DSM-38128 Attempting to create an IP filter with a Specific User setting results in a error and prevents the creation of any additional IP filters. Documentation updated to clarify this setting. Table 20. Issues Fixed in Storage Manager 2018 R1.
Fixed Issues Related to the Unisphere User Interface The following issues related to Unisphere are fixed in Storage Manager 2018 R1: Table 22. Issues Fixed in Storage Manager 2018 R1.10 Issue Description DSM-36740 Unisphere disconnects from the Storage Center when the peer controller of a dual-controller storage system is restarted. DSM-36605 The space usage information in the Storage Centers view is inaccurate.
Fixed Issues Related to the Storage Manager Virtual Appliance The following issues related to the Storage Manager Virtual Appliance are fixed in Storage Manager 2018 R1: Table 25. Issues Fixed in Storage Manager 2018 R1.20 Issue Description DSM-38216 The Storage Manager Virtual Appliance may not complete the domain join process. Table 26. Issues Fixed in Storage Manager 2018 R1.
Fixed Issues Related to Virtual Volumes The following issues related to virtual volumes are fixed in Storage Manager 2018 R1: Table 29. Issues Fixed in Storage Manager 2018 R1 Issue Description DSM-38035 VASA provider registration might fail if the hostname or Fully Qualified Domain name (FQDN) of the Storage Manager Data Collector server contains invalid characters. Valid characters for the hostname and FQDN are letters, numbers, a period (.), and a dash (-).
Issue Description Workaround: None DSM-16754 When replicating more than 16 volumes from a PS Series group to a Storage Center, Storage Manager displays replications in a Waiting state as Down. Workaround: Replicate no more than 16 volumes at a time. DSM-16737 Storage Manager does not allow you to set up a replication from a Storage Center to a PS Series group when creating a volume on the Storage Center. Workaround: Set up replication to the PS Series group using the Replicate Volume wizard.
Miscellaneous Open Issues The following open miscellaneous issues are in Storage Manager: Issue Description DSM-34466 Running a Nessus security scan on Storage Manager reports an SSL Medium Strength Cipher Suites Supported vulnerability. Workaround: None DSM-28532 After changing the Chargeback department of a volume that has the same index as a volume on a different Storage Center, Storage Manager might not show that the volume changed Chargeback departments.
Issue Description Workaround: Monitor alerts using the Group Manager, opening the Alerts view in Unisphere or opening the Events tab in Storage Manager. DSM-23693 Storage Manager displays a PS Series group as inactive after a controller failover on the PS Series group. Workaround: Remove the PS Series group from Storage Manager then add it back. DSM-17321 Storage Manager displays alerts and alarms for PS Series groups that have been cleared to the recycling bin in Group Manager.
Issue Description Workaround: Error message can be ignored. DSM-31875 The VMware host setup is configuring iSCSI HBA Login Timeout from 5 to 60 incorrectly. Workaround: Refer to VMware best practices documentation. DSM-28137 SRM planned failovers with Live Volumes fail when vMotion is not enabled in the environment. Workaround: Dell Storage Replication Adapter (SRA) with Stretched Storage and Live Volumes requires vMotion. Enable vMotion.
Issue Description DSM-20037 Creating a server using the Create Server from VMware vSphere or vCenter wizard fails if the host contains adapters that are not VMware software iSCSI adapters. Workaround: Create the server manually using the Create Server dialog box. DSM-15660 After adding disks to tier two in a three-tiered Storage Type that exceeds the limit for single redundancy level, tier three is forced to dual redundant instead of tier two.
Issue Description Workaround: View the threshold data in the Thresholds Alerts view. DSM-28859 The welcome screen for the Storage Manager Red Hat Linux client appears blank when the Color Depth of the Windows Remote Desktop Connection is set to Highest Quality (32 bit). Workaround: Set the Color Depth of the Windows Remote Desktop Connection to True Color (24 bit) or High Color (16 bit). DSM-26168 Storage Manager displays the option to delete when volumes and volume folders are selected.
Issue Description DSM-36253 When creating a new server, the Operating System information dialog box shows the Maximum Path Count as zero instead of 32 or unlimited. Workaround: None DSM-36243 Unisphere seems to allow users to remove the last virtual port from a fault domain and indicates that the attempt was successful even when the final port was not actually removed. Workaround: Do not attempt to remove the last port from a fault domain.
Open Issues Related to SupportAssist and Updating The following open issues are related to SupportAssist and updating systems: Issue Description DSM-36088 Occasionally, when starting a non-service affecting update for a Storage Center through the Data Collector, Storage Manager loses connectivity with the Storage Center. Workaround: The system automatically resolves the connectivity issue.
Issue Description DSM-24536 Using the characters < or > in fields in the settings for a user causes an error. Workaround: Do no use those characters. DSM-15445 Adding Storage Manager to Active Directory fails if you are using the distinguished name (DN) of a user. Workaround: Use the user principal name (UPN) to add Storage Manager to an Active Directory realm. DSM-12329 After unlocking a user, the status might not change to unlocked immediately. Workaround: Refresh the Storage Manager Client.
Open Issues Related to Virtual Volumes The following open issues are related to virtual volumes in Storage Manager 2018 R1. Table 31. Open Issues in Storage Manager 2018 R1 Issue Description DSM-16665 After upgrading an ESXi host from version 5.5 to 6.0, Dell Storage Manager does not properly reflect the host and its attributes as being ESXi 6 capable, in particular the recognition of the protocol endpoint. An extra artifact is that a VVol datastore is identified with improper size of 0 byes.
Issue Description • • Changing a storage container’s Data Reduction profiles might cause future fast cloned VMs to be created with mismatched Data Reduction profiles for the config and data VVols. If a user applies a VM Storage Policy to the original VM, the same changes apply to the data VVols of the fast clone VM and conversely. Workaround: None DSM-14806 Migrate or Clone operations on virtual machines with snapshots might fail if not enough space is available in the VVol datastore hosting the VM.
Issue Description DSM-11945 Even after unregistering VASA, powered-off VMs are accessible and VVol datastores are active. If you try to power on the VMs or create a new VM, vCenter eventually discovers that the VASA Provider is not present and it marks the VVol datastores as inactive. Workaround: None DSM-9825 If you create a storage container in Dell Storage Manager, and then create a datastore from vCenter, there could be a delay before the VASA Provider detects the datastore.
Provides instructions for using the Storage Manager software. • Storage Manager Online Help Provides context-sensitive help for the Storage Manager software, • Storage Manager Installation Guide Provides installation and setup instructions for the Storage Manager software. • Unisphere and Unisphere Central for SC Series Administrator’s Guide Provides instructions and information for managing storage systems using Unisphere and Unisphere Central for SC Series.