a. Click Add.
The Create iSCSI NAT Public Network/Initiator dialog box opens.
b. In the Public IPv4 Address field, type the IPv4 address for the iSCSI initiator or subnet for which NAT port forwarding
is required.
c. In the Subnet Mask field, type the subnet mask for the iSCSI initiator IP address or subnet.
d. Click OK.
The Create iSCSI NAT Public Network/Initiator dialog box closes.
9. Repeat the preceding steps for each additional iSCSI initiator IP address or subnet that requires port forwarding.
10. Click OK.
Modify NAT Port Forwarding for an iSCSI Fault Domain
Modify NAT port forwarding to change the port forwarding configuration or change the iSCSI initiators and subnets that require
port forwarding.
Prerequisites
The Storage Center iSCSI ports must be configured for virtual port mode.
For each Storage Center iSCSI control port and virtual port, a unique public IP address and TCP port pair must be reserved
on the router that performs NAT.
Steps
1. If you are connected to a Data Collector, select a Storage Center from the drop-down list in the left navigation pane of
Unisphere Central.
2. From the SYSTEM menu, click Ports.
The Ports view is displayed.
3. Click the Front End Ports tab.
4. Expand iSCSI and click the fault domain link.
The Fault Domain view is displayed.
5. On the Summary tab, click
(More Actions) and select Configure NAT Port Forwarding.
The Configure NAT Port Forwarding dialog box opens.
6. In the Port Forwarding Configuration area, modify port forwarding information for a Storage Center iSCSI port.
To add port forwarding information for an iSCSI port, click Add.
To modify port forwarding information for an iSCSI port, select the port, then click Edit.
To delete port forwarding information for an iSCSI port, select the port, then click Remove.
7. In the Public Networks/Initiators area, add or modify iSCSI initiator IP addresses or subnets that require port forwarding
to reach the Storage Center because it is separated from the Storage Center by a router performing NAT.
To add an iSCSI initiator IP address or subnet, click Add.
To modify an iSCSI initiator IP address or subnet, select it, then click Edit.
To delete an iSCSI initiator IP address or subnet, select it, then click Remove.
8. Click OK.
Configuring CHAP for iSCSI Fault Domains
When Challenge Handshake Authentication Protocol (CHAP) authentication is enabled, the Storage Center challenges each
iSCSI initiator in the fault domain for a shared secret (password). When CHAP is enabled it applies to all servers and remote
Storage Centers that connect to the fault domain.
NOTE:
When CHAP is enabled for an iSCSI fault domain, all iSCSI initiators in the fault domain (servers and Storage
Centers) must be configured to use CHAP. All iSCSI initiators that are not configured to use CHAP are no longer able to
communicate with the Storage Center iSCSI ports in the fault domain.
Configure CHAP for Servers in an iSCSI Fault Domain
When Challenge Handshake Authentication Protocol (CHAP) authentication is enabled (for unidirectional CHAP only), the
Storage Center (target) challenges each iSCSI initiator for a shared secret (password). Servers (remote initiators) must provide