Administrator Guide
Flash Only with Progression (Tier 1 to Tier 2)
The Flash Only with Progression storage prole performs initial writes on high-performance Tier 1 drives. Less active data progresses to
Tier 2, but remains on SSDs. This prole is useful for storing volumes with data that requires optimal read performance, such as golden
images, linked clones, and some databases.
Low Priority with Progression (Tier 3 to Tier 2)
The Low Priority with Progression storage prole directs initial writes to less expensive Tier 3 (RAID 10) drives, and then allows frequently
accessed data to progress to Tier 2. This prole is useful for migrating large amounts of data to Storage Center without overloading Tier 1
SSDs.
Storage Proles for SCv2000 Series Controllers
The following table summarizes the storage proles available to SCv2000 series controllers.
Name Initial Write Tier Tier (T) and RAID Levels RAID Tiering
Balanced 1
Writes: T1 RAID 10
Snapshots: T1 RAID 5/6
Between RAID types only
Maximize Performance 1
Writes: T1 RAID 10
Snapshots: T1 RAID 10
No
Maximize Eciency 1
Writes: T1 RAID 5/6
Snapshots: T1 RAID 5/6
No
Balanced
The Balanced storage prole balances eciency and performance for any volume using that storage prole.
When a volume uses the Balanced storage prole, all new data is written to RAID 10. When Storage Center creates a snapshot, Data
Progression moves snapshot data from RAID 10 to RAID 5/6.
Maximize Performance
Maximize Performance keeps new data and snapshot data on RAID 10 to increase performance. Maximize Performance is useful for
volumes with important and frequently used data.
Maximize Eciency
Maximize Eciency writes new data to RAID 5/6 and keeps snapshot data on RAID 5/6. Use Maximize Eciency for volumes with less-
important data and infrequently used data.
User Interface for Storage Center Management
Most storage conguration and management for an individual Storage Center is performed from the Storage view in the Storage Manager
Client. Select a Storage Center in the Storage navigation pane to view and manage it.
The following tabs appear in the display pane when a Storage Center is selected:
• Summary Tab
54
Storage Center Overview