Owners Manual

SCv3000 and SCv3020 Storage System
Hardware
The SCv3000 and SCv3020 storage system ships with Dell Enterprise Plus Value drives, two redundant power supply/cooling fan modules,
and two redundant storage controllers. Each storage controller contains the front-end, back-end, and management communication ports of
the storage system.
SCv3000 and SCv3020 Storage System Front-Panel
View
The front panel of the storage system contains power and status indicators, and a system identication button.
In addition, the hard drives are installed and removed through the front of the storage system chassis.
Figure 1. SCv3000 and SCv3020 Storage System Front-Panel View
Item
Name Icon Description
1 Power indicator Lights when the storage system power is on
O – No power
On steady green – At least one power supply is providing power to the storage
system
2 Status indicator Lights when the startup process for both storage controllers is complete with no
faults detected.
NOTE: The startup process can take 5–10 minutes or more.
O – One or both storage controllers are running startup routines, or a fault
has been detected during startup
On steady blue – Both storage controllers have completed the startup process
and are in normal operation
Blinking amber – Fault detected
1
6 SCv3000 and SCv3020 Storage System Hardware