Release Notes

Table 12. Known issues in Storage Center 7.5.1 (continued)
Issue Functional area Description Workaround/Resolution
condition where one of the Windows hosts
is isolated from both its peer and its
quorum witness.
SCOS-17981 Live Volume and
Replication
Server mappings may not be removed
completely when a server is removed from
a cluster using Storage Manager before the
server is removed from the cluster.
When a server is removed from one
Storage Center only, or a volume is
unmapped on one Storage Center only,
the persistent reservations might not stay
consistent between primary volume and
secondary volume.
Remove the server from the cluster
through the operating system first. After
the server is rebooted, remove the server
object using Storage Manager.
When removing a server from a cluster or
unmapping a volume, perform the following
steps:
1. Remove the server from the cluster, or
unmap the volume on the server side
before making changes on the Storage
Centers.
2. Delete the server on both Storage
Centers, or unmap the volume on both
Storage Centers.
SCOS-14322 Live Volume and
Replication
A one path to disk alert is generated
when a Live Volume is created and there is
only one replication path per controller.
None
ENHTKR-90 Live Volume and
Replication
When importing a volume, Storage
Manager does not allow you to select 0 as
the LUN number.
Change the LUN number of the volume to
0 after importing the volume.
SCOS-59639 Storage
Management
A controller might reset due to a timeout
caused by IPMI/KCS driver errors.
Set the IP address of the iDRAC (BMC) on
each controller to a non-routable address
such as 0.0.0.0.
SCOS-40588 Storage
Management
Connecting to a storage system through
Storage Manager Data Collector and
setting up an iSCSI fault domain in
legacy mode might result in the error
Unable to access controller
port information and an iSCSI fault
domain with only one port.
Use the Storage Manager Client to
connect directly to the storage system and
then set up an iSCSI fault domain in legacy
mode.
SCOS-22150 Storage
Management
In rare instances, a controller failover on an
SC7020 or SC5020 storage system might
prevent Secure Console access.
Contact technical support.
SCOS-22026 Storage
Management
Removing an HBA or deleting a server
object before unmapping it from volumes
might result in the server losing access
to volumes and prevent controller failover
from completing properly.
Contact technical support.
HPEM-541 Storage
Management
In rare instances, SC7020 updates do not
complete successfully and the Storage
Center might indicate that updates are still
required.
Contact technical support.
SCOS-62922 Vendors A Fibre Channel port may restart after
being plugged into a Brocade Fibre Channel
switch running Fabric OS v8.2.0, v8.2.1,
or v8.2.2 that also has multiple logical
switches configured.
Set the fabric.rdp_poll_cycle
setting to 0 in the switch configuration
for Fabric OS v8.2.0, v8.2.1, or v8.2.2.
This issue is fixed in Fabric OS v8.2.3 and
v9.0.0.
SQAI-9 Vendors An ESXi 5.5 (Update 3b) host using
FCoE and QLogic 8262 converged network
adapters (CNAs) might cause the host to
fail during controller failovers.
Update the QLogic firmware
on the adapter. The QLogic
firmware is available at https://