Administrator Guide

NOTE: After you click the Apply Conguration button, the conguration cannot be changed until after the Storage Center is
fully deployed.
Deploy the Storage Center
The Storage Center sets up the controller using the information provided on the previous pages.
1 The Storage Center performs system setup tasks. The Deploy Storage Center page displays the status of these tasks.
To learn more about the initialization process, click More information about Initialization.
If one or more of the system setup tasks fails, click Troubleshoot Initialization Error to learn how to resolve the issue.
If the Conguring Disks task fails, click View Disks to see the status of the drives detected by the Storage Center.
If any of the Storage Center front-end ports are down, the Storage Center Front-End Ports Down dialog box opens. Select the
ports that are not connected to the storage network, then click OK.
2 When all of the Storage Center setup tasks are complete, click Next.
Enter Key Management Server Settings
Specify key management server settings, such as hostname and port.
1 In the Hostname eld, type the host name or IP address of the key management server.
2 In the Port eld, type the number of a port with open communication with the key management server.
3 In the Timeout eld, type the amount of time in seconds after which the Storage Center should stop attempting to reconnect to the
key management server after a failure.
4 To add alternate key management servers, type the host name or IP address of another key management server in the Alternate
Hostnames area, and then click Add.
5 If the key management server requires a user name to validate the Storage Center certicate, enter the name in the Username eld.
6 If the key management server requires a password to validate the Storage Center certicate, enter the password in the Password
eld.
7 Click Browse next to the Root CA Certicate. Navigate to the location of the root CA certicate on your computer and select it.
8 Click Browse next to the certicate elds for the controllers. Navigate to the location of the controller certicates on your computer
and select them.
9 Click Next.
Create a Storage Type
Select the datapage size and redundancy level for the Storage Center.
1 Select a datapage size.
Standard (2 MB Datapage Size): Default datapage size, this selection is appropriate for most applications.
High Performance (512 KB Datapage Size): Appropriate for applications with high performance needs, or in environments in
which snapshots are taken frequently under heavy I/O. Selecting this size increases overhead and reduces the maximum available
space in the Storage Type. All-ash storage systems use 512 KB by default.
High Density (4 MB Datapage Size): Appropriate for systems that use a large amount of disk space and take snapshots
infrequently.
2 Select a redundancy type.
Redundant: Protects against the loss of any one drive (if single redundant) or any two drives (if dual redundant).
Non-Redundant: Uses RAID 0 in all classes, in all tiers. Data is striped but provides no redundancy. If one drive fails, all data is lost.
NOTE
: Non-Redundant is not recommended because data is not protected against a drive failure. Do not use non-
redundant storage for a volume unless the data has been backed up elsewhere.
80 Storage Center Deployment