Deployment Guide

SCv3000 and SCv3020 and One SCv300 and SCv320
Expansion Enclosure
This figure shows an SCv3000 and SCv3020 storage system cabled to one SCv300 and SCv320 expansion enclosure.
Figure 45. SCv3000 and SCv3020 and One SCv300 and SCv320 Expansion Enclosure
1. Storage system 2. Storage controller 1
3. Storage controller 2 4. Expansion enclosure
The following table describes the back-end SAS connections from an SCv3000 and SCv3020 storage system to one SCv300 and SCv320
expansion enclosure.
Table 2.
SCv3000 and SCv3020 Connected to One SCv300 and SCv320 Expansion Enclosure
Path Connections
Chain 1: Side A (orange)
1. Storage controller 1: port 1 to the expansion enclosure: top EMM, port 1
2. Expansion enclosure: top EMM, port 2 to storage controller 2: port 2
Chain 1: Side B (blue)
1. Storage controller 2: port 1 to the expansion enclosure: bottom EMM, port 1
2. Expansion enclosure: bottom EMM, port 2 to storage controller 1: port 2
48 Connect the Back-End Cabling