Deployment Guide

Figure 51. Connect the Power Cables
3. Connect the power cables plugged into the left power supply to one power distribution unit (PDU).
4. Connect the power cables plugged into the right power supply to a second power distribution unit (PDU).
5. Turn on the storage system by pressing the power switches on both power supply/cooling fan modules to the ON position.
CAUTION: Do not power off the storage system until it is discovered by Storage Manager. During the initial power
up, the storage system might take up to twenty minutes to boot completely.
Figure 52. Turn On the Storage System
NOTE:
If the LEDs on a storage controller do not turn on, the storage controller might not be fully seated in the storage
system chassis. If this issue occurs, press both power buttons to turn off the storage system. Reseat the storage
controller, and then press both power buttons again to turn on the storage system.
If the power supply units do not power on, confirm that the power source is 200 to 240 volts (V). The 200 to 240
V power supply units do not display any LED indications if they are plugged into a 110 V outlet.
Locate Your Service Tag
Your storage system is identified by a unique service tag and Express Service Code.
The Service Tag and Express Service Code are found on the front of the system by pulling out the information tag. Alternatively, the
information might be on a sticker on the back of the storage system chassis. This information is used by Dell to route support calls to the
appropriate personnel.This information is used by the manufacturer to route support calls to the appropriate personnel.
NOTE:
The Quick Resource Locator (QRL) code on the information tag is unique to your system. Scan the QRL to get
immediate access to your system information using your smart phone or tablet.
54 Deploy the Storage Center