White Papers

Power Supply Profile
Version 1.0.0a 29
Table 15 – CIM Elements: Power Supply Profile
Element Name Requirement Description
Classes
CIM_BaseMetricDefinition Optional See section 10.1
CIM_ElementCapabilities Conditional See section 10.2.
CIM_EnabledLogicalElementCapabilities Optional See sections 7.2 and 10.3.
CIM_IsSpare Optional See section 10.4.
CIM_MemberOfCollection Conditional See section 10.5.
CIM_NumericSensor Optional See section 10.6 and 10.7
CIM_OwningCollectionElement Conditional See section 10.14.
CIM_PowerSupply Mandatory See sections 7.1 and 10.8.
CIM_RedundancySet Optional See sections 7.7 and 10.9.
CIM_RegisteredProfile Mandatory See section 10.10.
CIM_Sensor Optional See section 10.11 and 10.12
CIM_SuppliesPower Optional See sections 7.6 and 10.15.
CIM_SystemDevice Mandatory See sections 7.6 and 10.11.
Indications
None defined in this profile
10.1 CIM_BaseMetricDefinition
The CIM_Sensor class is defined by the Sensors Profile. The requirements listed in Table 26 are in
addition to those mandated by the Sensors Profile.
Table 16 – Class: CIM_BaseMetricDefinition
Properties Requirement Description
Name Mandatory See section 7.10.
10.2 CIM_ElementCapabilities
CIM_ElementCapabilities is used to associate an instance of CIM_PowerSupply with an instance of
CIM_EnabledLogicalElementCapabilities that describes the capabilities of the CIM_PowerSupply
instance. CIM_ElementCapabilities is mandatory when the CIM_EnabledLogicalElementCapabilities
instance is instantiated.
Table 17 – CIM_ElementCapabilities
Properties Requirement Notes
ManagedElement Mandatory
Key: Shall reference the instance of
CIM_PowerSupply
Cardinality 1..* indicating one or more references
Capabilities Mandatory
Key: Shall reference the instance of
CIM_EnabledLogicalElementCapabilities
Cardinality 0..1 indicating zero or one reference