White Papers

Power Supply Profile
Version 1.0.0a 31
Table 21 – Class: CIM_NumericSensor
Properties Requirement Description
SensorType Mandatory SensorType shall be set to 13 (Power Consumption).
10.7 CIM_NumericSensor – Power Production Measurement Sensor
The CIM_NumericSensor class is defined by the Sensors Profile. The requirements listed in Table 21 are
in addition to those mandated by the Sensors Profile.
Table 22 – Class: CIM_NumericSensor
Properties Requirement Description
SensorType Mandatory SensorType shall be set to 14 (Power Production).
10.8 CIM_PowerSupply
CIM_PowerSupply is used to represent the power supply.
Table 23 – Class: CIM_PowerSupply
Properties and Methods Requirement Description
SystemCreationClassName Mandatory
Key
SystemName Mandatory
Key
CreationClassName Mandatory
Key
DeviceID Mandatory
Key
TotalOutputPower Mandatory
Shall match 0 when the power supply’s total output
power is unknown
ElementName Mandatory See section 7.8.
OperationalStatus Mandatory
HealthState Mandatory
EnabledState Mandatory See section 7.5.
RequestedState Mandatory See section 7.4.
RequestStateChange( ) Conditional See section 8.1.
10.9 CIM_RedundancySet
CIM_RedundancySet is used to represent the aggregation of redundant power supplies.
Table 24 – Class: CIM_RedundancySet
Properties and Methods Requirement Description
InstanceID Mandatory
Key
RedundancyStatus Mandatory
TypeOfSet Mandatory See section 7.7.1.
MinNumberNeeded Mandatory
Shall match 0 when the minimum number of power
supplies needed for the redundancy is unknown
ElementName Mandatory
Shall be formatted as a free-form string of variable
length (pattern “.*”)
Failover( ) Optional See section 8.1.1.