White Papers

Version 1.0.0 23
GatheringType
uint16
Mandatory
The property shall have value 3 (periodic)
Id
string
Mandatory
The property shall have value “AggrMetricDef:4
IsContinuous
boolean
Mandatory
The property shall have value TRUE
Name
string
Mandatory
The property shall have value "DMTF:System Input
Power"
ProgrammaticUnits
string
Mandatory
The property shall have value "watt"
SimpleFunction
uint16
Mandatory
The property shall have value 3 (Maximum)
TimeScope uint16 Mandatory The property shall have value 2 (Point)
7.4.2 DCIM_AggregationMetricValue 452
The following clauses define the requirements for the DCIM_AggregationMetricValue class. 453
DCIM_AggregationMetricValue is a derivation of CIM_AggregationMetricValue. 454
The DCIM_AggrMetricInstance association’s Dependent property shall reference 455
DCIM_AggregationMetricValue instances. 456
The DCIM_MetricForME association’s Dependent property shall reference 457
DCIM_AggregationMetricValue instances. 458
7.4.2.1 Resource URIs for WinRM® 459
The class Resource URI shall be “http://schemas.dell.com/wbem/wscim/1/cim-460
schema/2/DCIM_AggregationMetricValue?__cimnamespace=root/dcim” 461
The key property shall be the InstanceID. 462
The instance Resource URI for this DCIM_AggregationMetricValue instance shall be: 463
http://schemas.dell.com/wbem/wscim/1/cim-schema/2/DCIM_AggregationMetricValue? 464
?__cimnamespace=root/dcim+InstanceID=<InstanceID>” 465
7.4.2.2 Operations 466
The following table details the implemented operations on DCIM_AggregationMetricValue. 467
Table 15 – DCIM_AggregationMetricValue Operations 468
Operation Name
Requirements
Get
Mandatory
Enumerate
Mandatory
Associators
Mandatory
References
Mandatory
7.4.2.3 Properties 469
The following table details the requirements for implementing DCIM_AggregationMetricValue instance 470
representing maximum power consumption metric in Watts for Last Minute, Hour, Day and Week. The 471
most derived class name of this instance shall be DCIM_AggregationMetricValue. 472
If the column “Property Name” matches the property name, the property either shall have the value 473
denoted in the corresponding column “Additional Requirements, or shall be implemented according to 474
the requirements in the corresponding column “Additional Requirements. 475
Table 16DCIM_AggregationMetricValue: Maximum Power Consumption Metric for Last Minute, 476
Hour, Day and Week Properties 477
Property Name
Type
Requirement
Additional Requirements