White Papers

24 Version 1.0.0
Property Name
Type
Requirement
Additional Requirements
AggregationDuration
datetime
Mandatory
shall be in W3C representation in WS-CIM
with the corresponding value equal to 1
minute or 1 hour or 1 day or 1 week.
AggregationTimeStamp
datetime
Mandatory
shall be in W3C representation in WS-CIM
with the corresponding value equal to current
timestamp.
InstanceID
string
Mandatory
shall have one of the following values:
DCIM:System:Max:Power:1M
DCIM:System:Max:Power:1H
DCIM:System:Max:Power:1D
DCIM:System:Max:Power:1W
MetricDefinitionId
string
Mandatory
"AggrMetricDef:4"
MetricValue
string
Mandatory
shall be equal to the collection value for last 1
minute or 1 hour or 1 day or 1 week in whole
watts
TimeStamp
datetime
Mandatory
shall be in W3C representation in WS-CIM
with the corresponding value equal to the
value collection timestamp.
Volatile
boolean
Mandatory
TRUE
7.5 Minimum Power Consumption Metric for Last Minute, Hour, Day and Week 478
The following defines the requirements of the DCIM_AggregationMetricValue instance for the minimum 479
power consumption metric for last minute, hour, day, and week. 480
One instance of DCIM_AggregationMetricValue shall be instantiated for minimum power consumption last 481
minute. 482
One instance of DCIM_AggregationMetricValue shall be instantiated for minimum power consumption last 483
hour. 484
One instance of DCIM AggregationMetricValue shall be instantiated for minimum power consumption last 485
day. 486
One instance of DCIM_AggregationMetricValue shall be instantiated for minimum power consumption last 487
week. 488