26 Version 1.0.0
Property Name
Type
Requirement
Additional Requirements
GatheringType
uint16
Mandatory
The property shall have value 3 (periodic)
Id
string
Mandatory
The property shall have value “AggrMetricDef:1
IsContinuous
boolean
Mandatory
The property shall have value TRUE
Name
string
Mandatory
The property shall have value "DMTF:System Input Power"
ProgrammaticUnits
string
Mandatory
The property shall have value "watt"
SimpleFunction
uint16
Mandatory
The property shall have value 2 (Minimum)
TimeScope uint16 Mandatory The property shall have value 2 (Point)
7.5.2 DCIM_AggregationMetricValue 519
The following clauses define the requirements for the DCIM_AggregationMetricValue class. 520
DCIM_AggregationMetricValue is a derivation of CIM_AggregationMetricValue. 521
The DCIM_AggrMetricInstance association’s Dependent property shall reference 522
DCIM_AggregationMetricValue instances. 523
The DCIM_MetricForME association’s Dependent property shall reference 524
DCIM_AggregationMetricValue instances. 525
7.5.2.1 Resource URIs for WinRM® 526
The class Resource URI shall be “http://schemas.dell.com/wbem/wscim/1/cim-527
schema/2/DCIM_AggregationMetricValue?__cimnamespace=root/dcim” 528
The key property shall be the InstanceID. 529
The instance Resource URI for this DCIM_AggregationMetricValue instance shall be: 530
http://schemas.dell.com/wbem/wscim/1/cim-schema/2/DCIM_AggregationMetricValue? 531
?__cimnamespace=root/dcim+InstanceID=<InstanceID>” 532
7.5.2.2 Operations 533
The following table details the implemented operations on DCIM_AggregationMetricValue. 534
Table 19 – DCIM_AggregationMetricValue Operations 535
Operation Name
Requirements
Get
Mandatory
Enumerate
Mandatory
Associators
Mandatory
References
Mandatory
7.5.2.3 Properties 536
The following table details the requirements for implementing DCIM_AggregationMetricValue instance 537
representing minimum power consumption metric in Watts for Last Minute, Hour, Day and Week. The 538
most derived class name of this instance shall be DCIM_AggregationMetricValue. 539
If the column “Property Name” matches the property name, the property either shall have the value 540
denoted in the corresponding column “Additional Requirements, or shall be implemented according to 541
the requirements in the corresponding column “Additional Requirements. 542
543