White Papers

Version 1.0.0 35
Operation Name
Requirements
References
Mandatory
7.8.2.3 Properties 710
The following table details the requirements for implementing DCIM_BaseMetricValue instance 711
representing the instantaneous power consumption headroom metric. The most derived class name of 712
this instance shall be DCIM_BaseMetricValue. 713
If the column “Property Name” matches the property name, the property either shall have the value 714
denoted in the corresponding column “Additional Requirements, or shall be implemented according to 715
the requirements in the corresponding column “Additional Requirements. 716
Table 32DCIM_BaseMetricValue: Instantaneous Power Consumption Headroom Metric in 717
Amperes Properties 718
Property Name
Type
Requirement
Additional Requirements
Duration
datetime
Mandatory
The property shall be NULL.
InstanceID
string
Mandatory
The property shall have value
DCIM:System:Point:PowerHdrm:Cont
MetricDefinitionId
string
Mandatory
The property shall have value
DCIM:System:Point:Power
MetricValue
string
Mandatory
The property shall have value equal to
the value of the instantaneous power
headroom in watts.
TimeStamp
datetime
Mandatory
The property shall be in W3C
representation in WS-CIM with the
corresponding value equal to Current
timestamp
Volatile
boolean
Mandatory
The property shall have value TRUE
7.9 DCIM_MetricDefForME 719
The following clauses define the requirements for the DCIM_MetricDefForME class. 720
DCIM_MetricDefForME is derived from CIM_MetricDefForME. 721
7.9.1 Resource URIs for WinRM® 722
The class Resource URI shall be “http://schemas.dell.com/wbem/wscim/1/cim-723
schema/2/DCIM_MetricDefForME?__cimnamespace=root/dcim724
The key properties shall be the Antecedent and Dependent. 725
The instance Resource URI for this DCIM_MetricDefForME instance shall be: 726
http://schemas.dell.com/wbem/wscim/1/cim-schema/2/DCIM_MetricDefForME? 727
?__cimnamespace=root/dcim+Antecedent=<Reference To
728
DCIM_ComputerSystem>
+Dependent=<Reference to DCIM_BaseMetricDefinition or 729
DCIM_AggregationMetricDefinition> 730