BIOS and Boot Management Profile Document Number: DCIM1040 Document Type: Specification Document Status: Published Document Language: E Date: 2012-12-30 Version: 1.3.
THIS PROFILE IS FOR INFORMATIONAL PURPOSES ONLY, AND MAY CONTAIN TYPOGRAPHICAL ERRORS AND TECHBIOSAL INACCURACIES. THE CONTENT IS PROVIDED AS IS, WITHOUT EXPRESS OR IMPLIED WARRANTIES OF ANY KIND. ABSENT A SEPARATE AGREEMENT BETWEEN YOU AND DELL™ WITH REGARD TO FEEDBACK TfO DELL ON THIS PROFILE SPECIFICATION, YOU AGREE ANY FEEDBACK YOU PROVIDE TO DELL REGARDING THIS PROFILE SPECIFICATION WILL BE OWNED AND CAN BE FREELY USED BY DELL. © 2008 – 2012 Dell Inc. All rights reserved.
CONTENTS 1 2 3 Scope .................................................................................................................................................... 7 Normative References ........................................................................................................................... 7 Terms and Definitions ........................................................................................................................... 8 3.7 9 4 Symbols and Abbreviated Terms ......
Figures Figure 1 – BIOS and Boot Management Profile: Class Diagram – BIOS Management ............................. 11 Figure 2 – BIOS and Boot Management Profile: Boot Management .......................................................... 12 Tables Table 1 – Related Profiles ........................................................................................................................... 11 Table 2 – CIM Elements: BIOS and Boot Management Profile ....................................................
Table 42 – SetAttributes( ) Method: Parameters ......................................................................................... 48 Table 43 – SetAttributes( ) Method: Standard Messages ........................................................................... 48 Table 44 – SetAttribute( ) Method: Return Code Values ............................................................................. 49 Table 45 – SetAttribute( ) Method: Parameters...........................................................
BIOS and Boot Management Profile 1 2 1 3 4 5 6 The BIOS and Boot Management Profile extends the management capabilities of referencing profiles by adding the capability to represent the configuration of the system BIOS setup and to manage the boot of the system. The system BIOS setup is modeled with multiple attributes that allow configuration of the BIOS. 7 2 8 Refer to the following documents for more information.
34 o DCIM_BootConfigSetting.mof 35 o DCIM_BootSourceSetting.mof 36 o DCIM_BIOSEnumeration.mof 37 o DCIM_BIOSInteger.mof 38 o DCIM_BIOSService.mof 39 o DCIM_BIOSString.mof 40 o DCIM_BIOSPassword.mof 41 o DCIM_LCElementConformsToProfile 42 o DCIM_LCRegisteredProfile 43 3 Terms and Definitions 44 For the purposes of this document, the following terms and definitions apply. 45 46 3.1 47 48 3.2 49 50 51 3.3 52 53 54 3.4 55 56 3.5 57 58 3.
59 60 3.7 61 62 63 3.8 64 65 66 3.9 67 68 69 3.10 70 71 72 3.11 73 74 3.12 75 76 3.13 77 78 79 3.14 80 81 82 3.15 83 84 85 3.16 86 87 88 3.17 need not – Indicates a course of action permissible within the limits of the document. referencing profile – Indicates a profile that owns the definition of this class and can include a reference to this profile in its “Related Profiles” table.
89 4 Symbols and Abbreviated Terms 90 91 4.1 92 93 94 4.2 95 96 4.3 97 98 99 4.4 100 101 4.5 102 4.6 103 104 105 IPL – Initial Program Load, refers to the IPL list (an initial priority list of boot devices). An Initial Program Load Device is any device in the system that can boot and load an operating system. In standard AT machines, this is the floppy drive or hard drive. See BIOS Boot Specification. 106 107 108 109 110 4.
Table 1 – Related Profiles 126 Profile Name Organization Version Relationship Profile Registration Profile DMTF 1.0 Mandatory 127 6 Description 128 129 130 The BIOS and Boot Management Profile describes the BIOS setup configuration that includes boot management. The profile also describes the relationship of the BIOS classes to the DMTF and Dell profile version information. 131 Figure 1 shows the BIOS and Boot Management Profile.
143 144 Figure 2 shows the object diagram schema for the boot management feature of the BIOS and Boot Management Profile. For simplicity, the prefix CIM_ has been removed from the class names. 145 146 DCIM_BootConfigSetting represents each boot list. DCIM_BootSourceSetting represents each of the boot list boot devices or sources that are shown under their corresponding boot list.
155 7 Implementation Requirements 156 157 158 This section provides the requirements and guidelines to implement the properties of the classes. Methods are listed in section 8. Table 2 provides the instances of CIM Elements for this profile. Instances of the CIM Elements shall be implemented as described in Table 2.
169 170 171 172 The instance Resource URI for DCIM_BIOSEnumeration instance shall be: http://schemas.dell.com/wbem/wscim/1/cimschema/2/DCIM_BIOSEnumeration?__cimnamespace=root/dcim+InstanceID= BIOS.Setup.11: , 173 where is the AttributeName property value. 174 7.1.1.2 175 The following table details the operations implemented on the DCIM_BIOSEnumeration class Operations Table 3 – DCIM_BIOSEnumeration - Operations 176 Operation Name Get Enumerate DCIM_BIOSService.
Table 4 – Class: DCIM_BIOSEnumeration 183 Properties Type Requirements Additional Requirements InstanceID String Mandatory The property value shall be formed as follows: “BIOS.Setup.1-1:”. AttributeName String Mandatory The property value shall be from the “AttributeName” column in Tables in section 7.1.5. AttributeDisplayName String Mandatory The property value shall be from the “AttributeDisplayName” column in Tables in section 7.1.5.
196 where is the AttributeName property value. 197 7.1.2.2 198 The following table details the implemented operations on DCIM_BIOSString. Operations Table 5 – DCIM_BIOSString - Operations 199 Operation Name Get Enumerate DCIM_BIOSService.SetAttribute() DCIM_BIOSService.SetAttributes() Requirements Mandatory Mandatory Mandatory Mandatory Required Input Instance URI Class URI See section 8.1 See section 8.2 200 201 7.1.2.
Table 6 – Class: DCIM_BIOSString 206 Properties Type Requirements Additional Requirements InstanceID String Mandatory The property value shall be formed as follows: “BIOS.Setup.1-1:”. AttributeName String Mandatory The property value shall be from the “AttributeName” column in tables in section 7.1.5. AttributeDisplayName String Mandatory The property value shall be from the “AttributeDisplayName” column in Tables in section 7.1.5.
208 7.1.3 DCIM_BIOSInteger 209 210 This section describes the implementation of the DCIM_BIOSInteger class that represents an integer type BIOS attribute. This class shall be instantiated in the Implementation Namespace. 211 7.1.3.1 212 213 The class resource URI shall be “http://schemas.dell.com/wbem/wscim/1/cimschema/2/DCIM_BIOSInteger?__cimnamespace=root/dcim” 214 The key property shall be the InstanceID.
Table 8 – Class: DCIM_BIOSInteger 229 Properties Type Requirements Additional Requirements InstanceID String Mandatory The property value shall be formed as follows: “BIOS.Setup.1-1:”. AttributeName String Mandatory The property value shall be from the “AttributeName” column in Tables in section 7.1.5. AttributeDisplayName String Mandatory The property value shall be from the “AttributeDisplayName” column in Tables in section 7.1.5.
241 7.1.4.2 Operations 242 The following table details the operations implemented on the DCIM_BIOSPassword class. 243 244 NOTE: The.SetAttribute() and SetAttributes() methods of the DCIM_BIOSService class are NOT supported for DCIM_BIOSPassword class. Table 9 – DCIM_BIOSPassword - Operations 245 Operation Name Get Enumerate DCIM_BIOSService.ChangeBIOSPassord() Requirements Mandatory Mandatory Mandatory Required Input Instance URI Class URI See section 8.1 246 247 7.1.4.
Table 10 – Class: DCIM_BIOSPassword 252 Properties Type Requirements Additional Requirements InstanceID String Mandatory The property value shall be formed as follows: “BIOS.Setup.1-1:”. AttributeName String Mandatory The property value shall be from the “AttributeName” column in Tables in section 7.1.5.8. AttributeDisplayName String Mandatory The property value shall be from the “AttributeDisplayName” column in Tables in section 7.1.5.8.
Properties Type Requirements Additional Requirements PasswordState Uint16 Mandatory The property shall represent the current state of the password that the attribute represents. The property shall have one of the following values: 0 (Unknown) password state is not available, 2 (Installed) password is currently set or installed, 3 (Uninstalled) password is currently not set or is uninstalled, 4(Hardware Disabled) password is disabled by hardware jumper. 253 7.1.
Table 11 – DCIM_BIOSEnumeration Processor Settings 269 AttributeName Version 1.3.
AttributeName AttributeDisplayName IsReadOnly Display Order LogicalProc Logical Processor FALSE 301 Disabled Enabled ProcHyperTransport HyperTransport Technology FALSE 302 HT1 HT3 ProcHtAssist HT Assist FALSE 303 Disabled Enabled QpiSpeed QPI Speed FALSE 304 ProcVirtualization Virtualization Technology FALSE 305 Disabled Enabled DMA Virtualization Attribute Value 2 Dependant 306 Disabled Enabled 307 Disabled Enabled 308 Disabled Enabled
AttributeName ProcCStates 3 CorePerfBoost AttributeDisplayName IsReadOnly Display Order PossibleValues Processor C States FALSE 318 Disabled Enabled Core Performance Boost FALSE 330 Disabled Enabled 270 271 NOTE: 1 – Intel© QuickPath Interconnect is a point-to-point processor interconnect developed by Intel that replaces the Front Side Bus (FSB).
Table 12 – DCIM_BIOSString Processor Settings 280 AttributeName 281 282 283 Attribute Description IsReadOnly Display Order MinLength MaxLength Proc64bit Processor 64-bit Support TRUE 340 0 4 ProcCoreSpeed Processor Core Speed TRUE 341 0 16 ProcBusSpeed Processor Bus Speed TRUE 342 Proc1Id Family-ModelStepping TRUE 350 0 8 Proc1Brand Brand TRUE 351 0 80 Proc1L2Cache Level 2 Cache TRUE 352 0 16 Proc1L3Cache Level 3 Cache TRUE 353 0 16 Proc2Id Family-ModelSteppi
289 290 291 292 293 294 GroupDisplayName property shall be “SATA Settings”. The following table describes the values for the DCIM_BIOSEnumeration of this group. Each of the column headings correspond to a property name on the DCIM_BIOSEnumeration class. The column headers represent the properties of the DCIM_BIOSEnumeration class. Each of the cells represent the values of the properties. Each of the listed values under the PossibleValues header is an element of an array.
AttributeName Attribute Description IsReadOnly Display Order MinLength MaxLength SataPortBCapacity1 Capacity TRUE 411 0 8 SataPortCModel Model TRUE 413 0 40 SataPortCDriveType Drive Type TRUE 414 0 20 SataPortCCapacity1 Capacity TRUE 415 0 8 SataPortDModel Model TRUE 417 0 40 SataPortDDriveType Drive Type TRUE 418 0 20 SataPortDCapacity1 Capacity TRUE 419 0 8 SataPortEModel Model TRUE 421 0 40 SataPortEDriveType Drive Type TRUE 422 0 20 SataPortECa
306 307 308 309 The following table describes the values for the DCIM_BIOSEnumeration of this group. The column headers represent the properties of the DCIM_BIOSEnumeration class. Each of the cells represent the values of the properties. Each of the listed values under the PossibleValues header is an element of an array.
324 GroupID property shall be “SerialCommSettings”. 325 GroupDisplayName property shall be “Serial Communication”. 326 327 328 329 The following table describes the values for the DCIM_BIOSEnumeration of this group. The column headers represent the properties of the DCIM_BIOSEnumeration class. Each of the cells represent the values of the properties. Each of the listed values under the PossibleValues header is an element of an array.
Table 19 – DCIM_BIOSEnumeration System Profile Settings 342 AttributeName SysProfile AttributeDisplayName IsReadOnly System Profile Display Order 1202 PerfPerWattOptimizedOs PerfPerWattOptimizedDapc PerfOptimized Custom DenseCfgOptimized 1203 MaxPerf MinPwr SysDbpm OSDbpm 1204 MaxPerf 1333MHz 1067MHz 800MHz 317 Disabled Enabled 315 Disabled Enabled 318 Disabled Enabled Enabled Disabled 1206 Extended Standard Disabled 1207 Max
Table 20 – DCIM_BIOSEnumeration Integrated Devices 352 AttributeName AttributeDisplayName Integrated RAID Controller IntegratedRaid IsReadOnly Display Order 903 Disabled Enabled AllOn OnlyBackPortsOn AllOff 907 On Off 909 On Off 906 On Off 921 Disabled Enabled FALSE 905 User Accessible USB Ports Internal USB Port 1 UsbPorts FALSE FALSE InternalUsb1 Internal USB Port 2 FALSE InternalUsb2 InternalUsb Internal USB Port FALSE PossibleValues OsWatchdogTimer
AttributeName AttributeDisplayName Embedded Gb NIC3 IsReadOnly PossibleValues Disabled 919 Enabled EnabledPxe EnablediScsi Disabled 920 Enabled EnabledPxe EnablediScsi Disabled 913 DisabledOs Enabled 914 DisabledOs Enabled FALSE EmbNic3 Embedded Gb NIC4 Display Order FALSE EmbNic4 FALSE IntegratedNetwork1 Integrated Network 1 FALSE IntegratedNetwork2 Integrated Network 2 353 354 NOTE: 1 – The attribute’s read-only status (IsReadOnly property value) de
AttributeName TpmActivation TpmClear TcmSecurity TcmActivation TcmClear AttributeDisplayName TPM Activation TCM Clear TCM Security TCM Activation TPM Clear IsReadOnly TRUE TRUE FALSE Attribute Value 2,3 Dependant Attribute Value 2,4 Dependant Display Order OnNoPbm 1309 NoChange Activate Deactivate 1311 Yes No 1314 Off OnPbm OnNoPbm 1316 NoChange Activate Deactivate 1318 Yes No 1320 Disabled Enabled 1322 Disabled Enabled 1326 Last
AttributeName AttributeDisplayName SetupPassword Setup Password 381 382 383 IsReadOnly TRUE (but may be changed through the DCIM_BIOSService.ChangePassword() method. MinLength MaxLength 0 32 The following table describes the values for the DCIM_BIOSInteger of this group. The column headers represent the properties of the DCIM_BIOSInteger class. Each of the cells represent the values of the properties.
AttributeName RedundantMem AttributeDisplayName IsReadOnly Redundant Memory TRUE Snoop Filter FALSE SnoopFilter NodeInterleave MemLowPower Node Interleaving Low Power Mode MemVolt Memory Operating Voltage MemOpVoltage Memory Operating Voltage RedundantMemInUse Redundant Memory Configuration In Use Redundant Memory RedundantMemCfgValid Configuration Valid 396 397 NOTE: Feature 1 Dependant TRUE TRUE TRUE TRUE TURE Display Order PossibleValues Disabled Mirror IntraNodeMirror D
AttributeName Attribute Description IsReadOnly Display Order SysMemVolt TRUE VideoMem Video Memory TRUE 205 7.1.5.10 404 This section describes the attributes for miscellaneous settings configuration. 405 For the DCIM_BIOSEnumeration and DCIM_BIOSString: 0 8 0 16 Miscellaneous Settings 406 GroupID property shall be “MiscSettings”. 407 GroupDisplayName property shall be “Miscellaneous Settings”. The following table describes the values for the DCIM_BIOSEnumeration of this group.
422 423 424 The following table describes the values for the DCIM_BIOSString of this group. The column headers represent the properties of the DCIM_BIOSString class. Each of the cells represent the values of the properties.
Time Boot on DCIM_BootConfigSetting with InstanceID “OneTime” and source[] containing a single DCIM_BootSourSetting InstanceID from any boot list. boot device selected for one time boot. After the reboot, the boot list reverts to the original boot list. 433 434 435 DCIM_BootConfigSetting shall represent a collection of DCIM_BootSourceSetting instances; where the DCIM_BootSourceSetting.InstanceID substring that prefixes the first colon shall match the DCIM_BootConfigSetting.InstanceID value.
462 7.2.1.3 Properties 463 464 465 466 The table lists the properties implemented for DCIM_BootConfigSetting. The “Requirements” column shall denote whether the property is implemented (for requirement definitions, see section 3). The “Additional Requirements” column shall denote either possible values for the property, or requirements on the value formulation.
483 484 485 486 The instance Resource URI for DCIM_BootSourceSetting instance shall be: “http://schemas.dell.com/wbem/wscim/1/cimschema/2/DCIM_BootSourceSetting?__cimnamespace=root/dcim+InstanceID=” 487 7.2.2.2 488 The following table lists the operations implemented on DCIM_BootSourceSetting. Operations Table 32 – DCIM_BootSourceSetting – Operations 489 Operation Name Get Enumerate DCIM_BootConfigSetting. ChangeBootSourceState() DCIM_BootConfigSetting.
Table 33 – Class: DCIM_BootSourceSetting 495 Properties Type Requirement Additional Requirements InstanceID string Mandatory The property value shall have prefix from Table 29 “DCIM_BootConfigSetting.InstanceID” column followed by a unique ID representing the boot source. For example: UEFI:Disk.USBFront.21:3156051d1529b8f4f88c99f54b8953 50 (boot source belongs to UEFI bootlist) IPL:NIC.Slot.42:d0f2c6c736adb8c2238153293a0c02 6c (boot source belongs to IPL bootlist) BCV:RAID.Integrated.
Properties Type FailThroughSupported Requirement Additional Requirements Mandatory The property shall indicate the behavior of the boot source failure. The property shall have one of the following values: 0 = Unknown 1 = Is Supported indicates that the next boot source in the boot order shall be used. 2 = Is Not Supported indicates that the boot order is terminated and no other boot sources shall be used. 496 7.3 Service for Method Invocations 497 7.3.
Table 35 – Class: DCIM_BIOSService 521 Properties Type Requirement Description SystemCreationClassName string Mandatory The property value shall be “DCIM_ComputerSystem”. CreationClassName string Mandatory The property value shall be “DCIM_BIOSService”. SystemName string Mandatory The property value shall be “DCIM:ComputerSystem”. Name string Mandatory The property value shall be “DCIM:BIOSService” ElementName string Mandatory The property value shall be “BIOS Service”. 522 7.
539 7.4.1.3 Properties 540 541 542 543 544 The following table details the implemented properties for DCIM_LCRegisteredProfile instance representing BIOS and Boot Management Profile implementation. The “Requirements” column shall denote whether the property is implemented (for requirement definitions, see section 3.3, 3.4, and 3.6). The “Additional Requirements” column shall denote either possible values for the property, or requirements on the value formulation.
548 8 Methods 549 550 This section details the requirements for supporting intrinsic operations and extrinsic methods for the CIM elements defined by this profile. 551 8.1 552 The SetAttribute( ) method is used to set or change the value of a BIOS attribute.
Table 40 – SetAttribute( ) Method: Standard Messages 564 MessageID (OUT parameter) Message MessageArguments[] BIOS001 The command was successful BIOS002 Resource allocation failure BIOS003 Missing required parameter BIOS004 Invalid parameter value for BIOS005 Mismatch in AttributeName and AttributeValue count BIOS006 Configuration job already created, cannot set attribute on specified target until existing job is completed or is cancelled BIOS007 Configuration job already
573 574 Return code values for the SetAttributes( ) method are specified in Table 41, and parameters are specified in Table 42. 575 576 NOTE: Invoking the SetAttributes( ) method multiple times can result in the earlier requests being overwritten or lost.
MessageID (OUT parameter) Message MessageArguments[] BIOS016 AttributeValue cannot be changed for Disabled AttributeName %s Attribute Name LC062 An instance of Export or Import System Configuration is already running. 580 581 The SetAttribute( ) method is used to set or change the value of a BIOS attribute.
593 8.3 DCIM_BIOSService.ChangePassword ( ) 594 The ChangePassword( ) method is used to set or change the value of a BIOS attribute. 595 596 Invoking the ChangePassword( ) method shall change the value of the password attribute’s PendingValue property to the value specified by the AttributeValue. 597 598 Return code values for the ChangePassword( ) method are specified in Table 46 and parameters are specified in Table 47.
MessageID (OUT parameter) Message MessageArguments[] BIOS024 BIOS password authentication failed BIOS025 Unable to set BIOS password. Password is disabled by Jumper 605 8.4 DCIM_BIOSService.CreateTargetedConfigJob( ) 606 607 608 The CreateTargetedConfigJob( ) method is used to apply the pending values created by the SetAttribute, SetAttributes, ChangePassword, ChangeBootSourceState, and ChangeBootOrderByInstanceID methods.
621 622 623 Qualifiers Name Type Description/Values IN UntilTime String End time for the job execution in format: yyyymmddhhmmss. : If this parameter is not NULL, then ScheduledStartTime parameter shall also be specified. NOTE: This parameter has a dependency on “ScheduledStartTime” parameter. Both “ScheduledStartTime” and “UntilTime” parameters define a time window for scheduling the job(s). After scheduling, jobs are executed within the time window.
625 626 8.5 DCIM_BIOSService.DeletePendingConfiguration( ) 627 628 629 630 631 632 The DeletePendingConfiguration( ) method is used to cancel the pending values created by the SetAttribute and SetAttributes methods. The DeletePendingConfiguration( ) method cancels the pending configuration changes made before the configuration job is created with CreateTargetedConfigJob(). This method only operates on the pending changes prior to CreateTargetedConfigJob() being called.
642 643 644 645 646 Invoking the ChangeBootSourceState( ) method shall change the boot sources state and affect DCIM_BootSourceSetting.PendingEnabledStatus properties. Upon the successful invocation, the DCIM_BootSourceSetting.PendingEnabledStatus shall have the value specified by the EnabledState parameter for the DCIM_BootSourceSetting instances with the InstanceID property matching the InstanceID parameter value(s).
656 8.7 DCIM_BootConfigSetting.ChangeBootOrderByInstanceID( ) 657 658 The ChangeBootOrderByInstanceID( ) method is used to change the order of boot devices within the boot list. 659 660 661 Invoking the ChangeBootOrderByInstanceID( ) method shall order the boot devices in the list in accordance to the corresponding array element in the Source parameter array. The omitted boot devices in the Source parameter array shall be omitted in the boot list ordering.
Table 60 – ChangeBootOrderByInstanceID( ) Method: Standard Messages 686 MessageID (OUT parameter) Message MessageArguments[] BOOT001 The command was successful BOOT002 Resource allocation failure BOOT003 Method not supported BOOT004 Invalid number of Boot Source arguments BOOT005 Missing required parameter BOOT006 Invalid Boot Source InstanceID BOOT007 Boot Source does not belong to specified Boot Configuration BOOT008 Source argument contains more devices than are present on the system
DCIM_BIOSPassword ENUMERATE, GET User Privilege Required Login, Server Control DCIM_BIOSService.SetAttribute() INVOKE Login, Server Control LM_REMOTE_CONFIGU RATION DCIM_BIOSService.SetAttributes() INVOKE Login, Server Control LM_REMOTE_CONFIGU RATION DCIM_BIOSService. CreateTargetedConfigJob() INVOKE Login, Server Control LM_REMOTE_CONFIGU RATION DCIM_BIOSService. DeletePendingConfiguration() INVOKE Login, Server Control LM_REMOTE_CONFIGU RATION DCIM_BIOSService.
ANNEX A (informative) 700 701 702 BIOS Attribute Changes from Version 1.1 703 BIOS Change Categories 704 A.
727 Attribute FQDD Notes Deleted in this version. BIOS.Setup.1 Changed to SysProfile in this version. BIOS.Setup.1 Fan management removed from BIOS BIOS.Setup.1 This attribute is specific to iDPT (Monroe Technology) on Nehelem EX - 4 socket platforms (eg McCave) BIOS.Setup.1 Changed to several memory related attributes in this version. PowerMgmt FanPwrPerf MemDynamicPwr MemPwrPerf Changed in this version. Changed FQDD from BIOS.Setup.1 to System.Embedded.1 System.Embedded.
Attribute FQDD Notes BIOS.Setup.1 Group = SlotDisablement BIOS.Setup.1 Group = SlotDisablement BIOS.Setup.1 Group = SlotDisablement BIOS.Setup.1 Group = SlotDisablement BIOS.Setup.1 Group = SlotDisablement BIOS.Setup.1 Group = SlotDisablement BIOS.Setup.1 Group = ProcSettings BIOS.Setup.1 Group = IntegratedDevices BIOS.Setup.1 Group = IntegratedDevices Slot2 Slot3 Slot4 Slot5 Slot6 Slot7 QPISpeed IntegratedNetwork1 IntegratedNetwork2 60 Version 1.3.
ANNEX B (informative) 728 729 730 731 Change Log 732 Version Date 1.3.0 1.3.0 Description Added LC062 error message to the SetAttribute(), SetAttributes(), CreateTargetedConfigJob(), and DeletePendingConfiguration() methods. 9/28/2012 Correct privilege of BIOSPassword(Enum/Get) to Login, Server Control 733 734 735 Version 1.3.