White Papers

Version 1.2.0 11
7 Implementation Description 334
This section describes the requirements and guidelines for implementing RAID profile. 335
Table 2 shows the instances of CIM Elements for this profile. Instances of the CIM Elements shall be 336
implemented as described in Table 2. 337
Table 2 – CIM Elements: RAID Profile 338
Element Name Requirement Description
Classes
DCIM_RAIDService Mandatory See section 7.3
DCIM_ControllerView Mandatory See section 7.1.1
DCIM_EnclosureView Mandatory See section 7.1.2
DCIM_VirtualDiskView Mandatory See section 7.1.3
DCIM_PhysicalDiskView Mandatory See section 7.1.4
DCIM_ControllerBatteryView Mandatory See section 7.1.5
DCIM_EnclosureEMMView Mandatory See section 7.1.6
DCIM_EnclosurePSUView Mandatory See section 7.1.7
DCIM_EnclosureFanSensor Mandatory See section 7.1.8
DCIM_EnclosureTemperatureSensor Mandatory See section 7.1.9
DCIM_RAIDEnumeration Mandatory See section 7.2.1
DCIM_RAIDString Mandatory See section 7.2.2
DCIM_RAIDInteger Mandatory See section 7.2.3
DCIM_LCElementConformsToProfile Mandatory See section 7.4
DCIM_LCRegisteredProfile Mandatory See section 7.4
Indications
None defined in this profile
339
7.1 View Classes 340
The view classes represent the properties and status of the storage devices. The FQDD property 341
correlates the view to a specific device such as RAID.Integrated.1-1 for an integrated RAID controller.. 342
7.1.1 Controller View - DCIM_ControllerView 343
This section describes the implementation for the DCIM_ControllerView class. This class shall be 344
instantiated in the Implementation Namespace: root/dcim. 345
7.1.1.1 Resource URIs for WinRM
®
346
The class Resource URI shall be “http://schemas.dell.com/wbem/wscim/1/cim-347
schema/2/DCIM_ControllerView?__cimnamespace=root/dcim348
The key property shall be the InstanceID. 349